| 数据搜索系统,热门电子元器件搜索 |
|
MAS6503 数据表(PDF) 16 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6503 数据表(HTML) 16 Page - Micro Analog systems |
|
16 / 34 page ![]() DA6503.005 14 December 2016 16 (34) MEASUREMENT CONTROL REGISTER 2 (E3/63HEX) Measurement control register 2 (E3/63HEX) configures second half of the measurement settings and also starts the measurement. See table 4. OSRS bits select over sampling ratio (OSR) setting from five options. The OSR selection affects both measurement resolution and conversion time. The best resolution is achieved at highest OSR setting 4096 but the conversion time is longest. The fastest conversion is achieved at lowest OSR setting 256 but the achieved resolution is lowest. Typically highest OSR setting is used only in the most precise measurement such as pressure measurement. Medium or lowest OSR setting is typically sufficient in the temperature measurement. The lowest OSR setting can be used in the least precision VDD level monitoring measurement. RSENSOR bits select sensor resistance from eight options from 2.0kΩ up to 10 kΩ. Selecting proper RSENSOR according to sensor resistance is important only for the temperature measurement mode. See also Temperature Measurement Configuration in the Application Information section. PTS bits select between three measurement modes; pressure, temperature and VDD level monitoring modes. The conversion starts right after writing data byte to the Measurement control register 2. Thus to start new conversion the measurement configuration data has to be written first to Measurement control register 1 and after that to the Measurement control register 2. To avoid disturbing the running measurement the serial communication with MAS6503 should be kept idle during conversions. The EOC pin goes low when the conversion starts and it returns back high when the conversion is ready. Table 4. Measurement control register 2 (E3/63HEX) description Bit Number Bit Name Description Value Function 7-5 OSRS Over Sampling Ratio (OSR) Selection 000 001 010 011 100 OSR = 256 OSR = 512 OSR = 1024 OSR = 2048 OSR = 4096 4-2 RSENSOR Sensor Resistance 000 001 010 011 100 101 110 111 2.0kΩ 2.5kΩ 3.0kΩ 3.5kΩ 4.0kΩ 4.5kΩ 5.0kΩ 10.0kΩ 1-0 PTS Pressure/ Temperature/ VDD Level Monitoring Mode Selection 00 01 10 11 Temperature mode VDD level monitoring mode Pressure mode - |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |