| 数据搜索系统,热门电子元器件搜索 |
|
MAS6503 数据表(PDF) 9 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6503 数据表(HTML) 9 Page - Micro Analog systems |
|
9 / 34 page ![]() DA6503.005 14 December 2016 9 (34) OPERATING MODES After connecting the power supply the device is reset by on-chip power on reset (POR) circuit and then set to standby mode. The POR circuit works only for supply voltage rise rates faster than max 1ms rise time. To provide reset in all supply rise conditions it is recommended to reset the device manually after every power up (VDD rise) either via the XCLR pin or via the serial bus using the reset register. MAS6503 has three operating modes, pressure, temperature and VDD level monitoring mode. In the pressure mode the pressure dependent sensor bridge voltage is connected to the ADC input. In the temperature measurement mode the resistive sensor bridge is connected into a Wheatstone bridge configuration together with four internal resistors (see Temperature Measurement Configuration in the Application Information chapter). The formed Wheatstone bridge output voltage is connected to the ADC input. It is proportional to absolute temperature. In the VDD level monitoring mode an internal bandgap voltage is connected to the ADC input but the ratiometric ADC references are allowed to follow supply voltage by disabling the internal regulator. The supply voltage monitoring can be useful feature especially in battery operated systems. Switching between pressure, temperature and VDD level monitoring modes is done via the single ADC control register. The measurement configuration includes selection of over sampling ratio, input signal range, offset and sensor resistance. By writing two 8-bit configuration data to two ADC control registers a new A/D conversion is started. MAS6503 includes a 256-bit EEPROM memory for storing trimming and calibration data on chip. 16- bits of EEPROM are reserved for internal oscillator trimming and programmable I2C device address but the remaining 240-bits are free for calibration and other data. The stored calibration data should comprise of calibration and temperature compensation coefficients which can be used to calculate accurate calibrated pressure and temperature measurement results from the non-calibrated measurement results. All calculations need to be done in the external micro controller unit (MCU). A calibrated MAS6503 sensor system is operated as illustrated in figure 2. The calibration and compensation coefficients need to be read to the MCU memory only once. From each pair of pressure and temperature measurements results the accurate pressure and temperature values are then calculated by using the external MCU. All communication with MAS6503 is done using a 4-wire SPI bus or a 2-wire I2C bus. Starting an A/D conversion, reading out the conversion result and reading and writing data from and to the EEPROM memory are all accomplished via serial bus communication. In addition to the serial bus the digital interface includes also end-of-conversion (EOC) and master reset (XCLR) pins. See Serial interface in the following Serial Data Interface Control chapter. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |