6 / 89 page ![]() Data Sheet ADBMS1818 SPECIFICATIONS analog.com Rev. 0 | 6 of 89 Table 3. Parameter Test Conditions/Comments Min Typ Max Unit C13 Voltage TME specifications met, apply over the full specified temperature range 2.5 V C7 Voltage TME specifications met, apply over the full specified temperature range 1 V VREG Supply Voltage (VREG) TME supply rejection < 1 mV/V, apply over the full specified temperature range 4.5 5 5.5 V DRIVE Output Voltage Sourcing 1 µA 5.4 5.7 5.9 V Sourcing 1 µA, apply over the full specified temperature range 5.2 5.7 6.1 V Sourcing 500 µA, apply over the full specified temperature range 5.1 5.7 6.1 V Digital Supply Voltage (VREGD) Apply over the full specified temperature range 2.7 3 3.6 V Discharge Switch On Resistance VCELL = 3.6 V, apply over the full specified temperature range 4 10 Ω Thermal Shutdown Temperature 150 °C Watchdog Timer Pin Low (VOL(WDT)) WDT pin sinking 4 mA, apply over the full specified temperature range 0.4 V General-Purpose I/O Pin Low (VOL(GPIO)) GPIO pin sinking 4 mA (used as digital output), apply over the full specified temperature range 0.4 V 1 The active state current is calculated from dc measurements. The active state current is the additional average supply current into VREG when there are continuous 1 MHz communications on the isoSPI ports with 50% data 1s and 50% data 0s. Slower clock rates reduce the supply current. ADC TIMING SPECIFICATIONS Table 4. Parameter Test Conditions/Comments Min Typ Max Unit (tCYCLE) (See Figure 55, Figure 56, and Figure 58) Measurement and Calibration Cycle Time When Starting from the REFUP State in Normal Mode Measure 18 cells, apply over the full specified temperature range 2027 2343 2488 µs Measure 3 cells, apply over the full specified temperature range 352 407 432 µs Measure 18 cells and 2 GPIO inputs, apply over the full specified temperature range 2717 3140 3335 µs Measurement and Calibration Cycle Time When Starting from the REFUP State in Filtered Mode Measure 18 cells, apply over the full specified temperature range 174.2 201.3 213.8 ms Measure 3 cells, apply over the full specified temperature range 29.1 33.6 35.7 ms Measure 18 cells and 2 GPIO inputs, apply over the full specified temperature range 232.3 268.5 285.1 ms Measurement and Calibration Cycle Time When Starting from the REFUP State in Fast Mode Measure 18 cells, apply over the full specified temperature range 970 1121 1191 µs Measure 3 cells, apply over the full specified temperature range 176 203 215 µs Measure 18 cells and 2 GPIO inputs, apply over the full specified temperature range 1307 1511 1605 µs Skew Time (tSKEW1). The Time Difference Between Cell 18 and GPIO1 Measurements, Command = ADCVAX (See Figure 58) Fast mode, apply over the full specified temperature range 168 194 206 µs Normal mode, apply over the full specified temperature range 470 543 577 µs Skew Time(tSKEW2). The Time Difference Between Cell 18 and Cell 1 Measurements, Command = ADCV (See Figure 55) Fast mode, apply over the full specified temperature range 202 233 248 µs Normal mode, apply over the full specified temperature range 580 670 711 µs Regulator Start-Up Time (tWAKE) VREG generated from the DRIVE pin (see Figure 84), apply over the full specified temperature range 200 400 µs |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |