| 数据搜索系统,热门电子元器件搜索 |
|
ADBMS1818ASWZ-R7 数据表(PDF) 74 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADBMS1818ASWZ-R7 数据表(HTML) 74 Page - Analog Devices |
|
74 / 89 page ![]() Data Sheet ADBMS1818 APPLICATIONS INFORMATION analog.com Rev. 0 | 74 of 89 DISCHARGE CONTROL DURING CELL MEASUREMENTS If the discharge permitted (DCP) bit is high at the time of a cell measurement command, the S pin discharge states do not change during cell measurements. If the DCP bit is low, S pin discharge states are disabled while the corresponding cell or adjacent cells are being measured. If using an external discharge transistor, the relatively low 1 kΩ impedance of the internal ADBMS1818 PMOS transistors allow the discharge currents to fully turn off before the cell measurement. Table 71 shows the ADCV command with DCP = 0. In this table, off indicates that the S pin discharge is forced off irrespective of the state of the corresponding DCC bit. On indicates that the S pin discharge remains on during the measurement period if it was on prior to the measurement command. In some cases, it is not possible for the automatic discharge control to eliminate all measurement error caused by running the discharges. This is due to the discharge transistor not turning off fast enough for the cell voltage to completely settle before the measurement starts. For the best measurement accuracy when running discharge, the mute and unmute commands must be used. The mute command can be issued to temporarily disable all discharge transistors before the ADCV command is issued. After the cell conversion completes, an unmute command can be sent to reenable all discharge transistors that were previously on. Using this method maximizes the measurement accuracy with a very small time penalty. Method to Verify Discharge Circuits When using the internal discharge feature, the ability to verify discharge functionality can be implemented in the software. In applications using an external discharge MOSFET, an additional resistor can be added between the battery cell and the source of the discharge MOSFET, which allows the system to test discharge functionality. Table 71. Discharge Control During an ADCV Command with DCP = 0 Discharge Pin Cell Measurement Periods Cell Calibration Periods Cell 1, Cell 7, Cell 13 Cell 2, Cell 8, Cell 14 Cell 3, Cell 9, Cell 15 Cell 4, Cell 10, Cell 16 Cell 5, Cell 11, Cell 17 Cell 6, Cell 12, Cell 18 Cell 1, Cell 7, Cell 13 Cell 2, Cell 8, Cell 14 Cell 3, Cell 9, Cell 15 Cell 4, Cell 10, Cell 16 Cell 5, Cell 11, Cell 17 Cell 6, Cell 12, Cell 18 t0 to t1M t1M to t2M t2M to t3M t3M to t4M t4M to t5M t5M to t6M t6M to t1C t1C to t2C t2C to t3C t3C to t4C t4C to t5C t5C to t6C S1 Off Off On On On Off Off Off On On On Off S2 Off Off Off On On On Off Off Off On On On S3 On Off Off Off On On On Off Off Off On On S4 On On Off Off Off On On On Off Off Off On S5 On On On Off Off Off On On On Off Off Off S6 Off On On On Off Off Off On On On Off Off S7 Off Off On On On Off Off Off On On On Off S8 Off Off Off On On On Off Off Off On On On S9 On Off Off Off On On On Off Off Off On On S10 On On Off Off Off On On On Off Off Off On S11 On On On Off Off Off On On On Off Off Off S12 Off On On On Off Off Off On On On Off Off S13 Off Off On On On Off Off Off On On On Off S14 Off Off Off On On On Off Off Off On On On S15 On Off Off Off On On On Off Off Off On On S16 On On Off Off Off On On On Off Off Off On S17 On On On Off Off Off On On On Off Off Off S18 Off On On On Off Off Off On On On Off Off |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |