| 数据搜索系统,热门电子元器件搜索 |
|
ADRF6750ACPZ-R7 数据表(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADRF6750ACPZ-R7 数据表(HTML) 19 Page - Analog Devices |
|
19 / 40 page ![]() ADRF6750 Rev. A | Page 19 of 40 U3 CLR2 Q2 D2 U2 DOWN UP HI HI CP –IN +IN CHARGE PUMP DELAY CLR1 Q1 D1 U1 Figure 55. PFD Simplified Schematic Lock Detect (LDET) LDET (Pin 44) signals when the PLL has achieved lock to an error frequency of less than 100 Hz. On a write to Register CR0, a new PLL acquisition cycle starts, and the LDET signal goes low. When lock has been achieved, this signal returns high. Voltage-Controlled Oscillator (VCO) The VCO core in the ADRF6750 consists of two separate VCOs, each with 16 overlapping bands. Figure 56 shows an acquisition plot demonstrating both the VCO overlap at roughly 1260 MHz and the multiple overlapping bands within each VCO. The choice of two 16-band VCOs allows a wide frequency range to be covered without a large VCO sensitivity (KVCO) and resultant poor phase noise and spurious performance. Note that the VCO range is larger than the 2× LO frequency range of the part to ensure that the device has enough margin to cover the full frequency range over all conditions. 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 800 900 1000 1100 1200 1300 1400 1500 1600 1700 LO FREQUENCY (MHz) Figure 56. VTUNE vs. LO Frequency The correct VCO and band are chosen automatically by the VCO and band select circuitry when Register CR0 is updated. This is referred to as autocalibration. The autocalibration time is set to 50 μs. During this time, the VCO VTUNE is disconnected from the output of the loop filter and is connected to an internal reference voltage. A typical frequency acquisition is shown in Figure 57. 10 100 1k 10k 100k 1M 10M 100M 1G 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 TIME (µs) AUTOCAL TIME (µs) ACQUISITION TO 100Hz Figure 57. PLL Acquisition After autocalibration, normal PLL action resumes and the correct frequency is acquired to within a frequency error of 100 Hz in 170 μs typically. For a maximum cumulative step of 100 kHz, autocalibration can be turned off by Register CR24, Bit 0. This enables cumu- lative PLL acquisitions of 100 kHz or less to occur without the autocalibration procedure, which improves acquisition times significantly (see Figure 58). 10 100 1k 10k 100k 0 50 100 150 200 TIME (µs) ACQUISITION TO 100Hz Figure 58. PLL Acquisition Without Autocalibration for 100 kHz Step The VCO displays a variation of KVCO as VTUNE varies within the band and from band to band. Figure 59 shows how the KVCO varies across the full LO frequency range. Also shown is the average value for each of the frequency bands. Figure 59 is useful when calculating the loop filter bandwidth and individual loop filter components. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |