| 数据搜索系统,热门电子元器件搜索 |
|
AD9923ABBCZ 数据表(PDF) 59 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9923ABBCZ 数据表(HTML) 59 Page - Analog Devices |
|
59 / 88 page ![]() AD9923A Rev. 0 | Page 59 of 88 Table 41. Power-Up Register Write Sequence Register Address Data Description SW_RST 0x10 0x01 Resets all registers to default values 0x20 to 0xFFF User defined Horizontal, vertical, shutter timing STANDBY 0x00 0x04 Powers up the AFE TEST3 0xEA 0x60 Set TEST3 register to required value OSC_RST 0x16 0x01 Resets crystal oscillator circuit TGCORE_RSTB 0x15 0x01 Resets internal timing core MASTER 0x20 0x01 Configures master mode OUTCONTROL 0x11 0x01 Enables all outputs after SYNC SYNCPOL 0x13 0x01 SYNC active polarity (for software SYNC only) VD HD SUSPEND SYNC HL, H1 TO H4, RG, XV1 TO XV13, VSG1 TO VSG8, SUBCK NOTES 1. THE SYNC RISING EDGE RESETS VD/HD AND COUNTERS TO 0. 2. SYNC POLARITY IS PROGRAMMABLE USING SYNCPOL REGISTER (ADDR 0x13). 3. DURING SYNC LOW, ALL INTERNAL COUNTERS ARE RESET AND VD/HD CAN BE SUSPENDED USING THE SYNCSUSPEND REGISTER (ADDR 0x14). 4. IF SYNCSUSPEND = 1, VERTICAL CLOCKS, H1 TO H4, AND RG ARE HELD AT THE SAME POLARITY SPECIFIED BY OUTCONTROL = LOW. 5. IF SYNCSUSPEND = 0, ALL CLOCK OUTPUTS CONTINUE TO OPERATE NORMALLY UNTIL SYNC RESET EDGE. Figure 76. SYNC Timing to Synchronize AD9923A with External Timing Generating Software Sync Without External Sync Signal If an external sync pulse is not available, it is possible to generate an internal sync pulse by writing to the SYNCPOL register (Address 0x13). If the software SYNC option is used, the SYNC input (Pin 35) should be low (VSS) during the power-up proce- dure. After the power-up procedure is complete, the SYNC pin can be used as an output by setting the SYNCENABLE register low (Address 0x12). After power-up, follow Step 1 to Step 9 of the procedure in the Recommended Power-Up Sequence for Master Mode section. For Step 10, instead of using the external sync pulse, write 1 to the SYNCPOL register to generate an internal sync pulse and begin the timing operation. SYNC During Master Mode Operation The SYNC input can be used anytime during master mode operation to synchronize the AD9923A counters with external timing, as shown in Figure 76. To suspend operation of the digital outputs during the SYNC operation, set the SYNCSUSPEND register (Address 0x14) to 1. If SYNCSUSPEND = 1, the polarities of the outputs are held at the same state as when OUTCONTROL = low, as shown in Table 42 and Table 43. Power-Up and Synchronization in Slave Mode The power-up procedure for slave mode operation is the same as the procedure described for master mode operation, with two exceptions: • Eliminate Step 8. Do not configure the part for master mode timing. • No sync pulse is required in slave mode. Substitute Step 10 with starting the external VD and HD signals. This synchronizes the part, allows the register updates, and starts the timing operation. Note that DCLK does not begin to transition until Step 7 is complete. When the AD9923A is in slave mode, the VD/HD inputs synchronize the internal counters. After a falling edge of VD, there is a latency of 34 master clock edges (CLI) after the falling edge of HD until the internal H-counter is reset. The reset operation is shown in Figure 77. Note that if SHDLOC is set so that the 3 ns minimum delay between the rising edge of SLI and the falling edge of the internal SHD signal is not met, the internal H-counter can reset after only 33 master clock edges (CLI). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |