| 数据搜索系统,热门电子元器件搜索 |
|
AD9923ABBCZ 数据表(PDF) 76 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9923ABBCZ 数据表(HTML) 76 Page - Analog Devices |
|
76 / 88 page ![]() AD9923A Rev. 0 | Page 76 of 88 Address (Hex) Data Bits Default Value Update Type Name Description [6]: EXPOSURE. [7]: READOUT. Note that if EXPOSURE and READOUT are triggered together, READOUT occurs immediately after the exposure is complete. 62 [2:0] 2 VD READOUTNUM Number of fields to suppress the SUBCK pulses during READOUT. 63 [11:0] 0 VD EXPOSURENUM Number of fields to suppress the SUBCK and VSG pulses during exposure. [12] 0 VDHDOFF Disable VD and HD during exposure. 0: enable. 1: disable. 64 [11:0] 0 SG SUBSUPPRESS Number of SUBCK pulses to suppress after VSG line. [23:12] 0 SUBCKNUM Number of SUBCK pulses per field. 65 [1:0] 0 SG SUBCKMASK Additional masking of SUBCK output. 0: no mask. 1: begin mask on VD edge. 2: mask using internal SHUT3 signal. 3: same as 1 and 2 (1 has priority). 66 [0] 1 SG SUBCKPOL SUBCK pulse start polarity. 67 [12:0] 1FFF SG SUBCK1TOG1 First SUBCK Pulse Toggle Position 1. [25:13] 1FFF SUBCK1TOG2 First SUBCK Pulse Toggle Position 2. 68 [12:0] 1FFF SG SUBCK2TOG1 Second SUBCK Pulse Toggle Position 1. [25:13] 1FFF SUBCK2TOG2 Second SUBCK Pulse Toggle Position 2. 69 [0] 0 VD VSUB0_MODE VSUB0 readout mode. 0: Mode 0. 1: Mode 1. [1] 0 VSUB0_KEEPON VSUB0 keep-on mode. 0: turn VUB0 off after READOUT or at next VD. 1: keep VSUB0 active beyond READOUT, until reset to 0. 6A [11:0] 0 VD VSUB0_ON VSUB0 on position. [12] 0 Unused Must be set to 0. [13] 1 VSUB0POL VSUB0 start polarity. 6B [0] 0 VD VSUB1_MODE VSUB1 readout mode. 0: Mode 0. 1: Mode 1. [1] 0 VSUB1_KEEPON VSUB1 keep on mode. 1: keep VSUB1 active beyond readout. 6C [11:0] 0 VD VSUB1_ON VSUB1 on position. [12] 0 Unused Must be set to 0. [13] 1 VSUB1POL VSUB1 start polarity. 6D [0] 0 VD SHUT0_ON SHUT0 manual control of signal. 0: off. 1: on. [1] 1 SHUT0POL SHUT0 active polarity. 1: on state produces high output. [2] 0 SHUT0_MAN SHUT0 manual control enable. 0: disable. 1: enable manual control. 6E [11:0] 0 VD SHUT0_ON_FD SHUT0 field on position. Ignored during manual or nonshutter mode. 6F [11:0] 0 VD SHUT0_ON_LN SHUT0 line on position. [12] 0 Unused Must be set to 0. [25:13] 0 VD SHUT0_ON_PX SHUT0 pixel on position. 70 [11:0] 0 VD SHUT0_OFF_FD SHUT0 field off position. Ignored during manual or nonshutter mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |