数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

AD9923ABBCZ 数据表(PDF) 18 Page - Analog Devices

部件名 AD9923ABBCZ
功能描述  CCD Signal Processor with V-Driver and Precision Timing??Generator
PDF  88 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  AD [Analog Devices]
网页  http://www.analog.com
标志 AD - Analog Devices

AD9923ABBCZ 数据表(HTML) 18 Page - Analog Devices

Back Button AD9923ABBCZ Datasheet HTML 14Page - Analog Devices AD9923ABBCZ Datasheet HTML 15Page - Analog Devices AD9923ABBCZ Datasheet HTML 16Page - Analog Devices AD9923ABBCZ Datasheet HTML 17Page - Analog Devices AD9923ABBCZ Datasheet HTML 18Page - Analog Devices AD9923ABBCZ Datasheet HTML 19Page - Analog Devices AD9923ABBCZ Datasheet HTML 20Page - Analog Devices AD9923ABBCZ Datasheet HTML 21Page - Analog Devices AD9923ABBCZ Datasheet HTML 22Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 88 page
background image
AD9923A
Rev. 0 | Page 18 of 88
HORIZONTAL CLAMPING AND BLANKING
The AD9923A horizontal clamping and blanking pulses are
fully programmable to suit a variety of applications. Individual
controls are provided for CLPOB, PBLK, and HBLK during
different regions of each field. This allows dark pixel clamping
and blanking patterns to be changed at each stage of the readout
to accommodate different image transfer timing and high speed
line shifts.
Individual CLPOB and PBLK Patterns
The AFE horizontal timing consists of CLPOB and PBLK, as
shown in Figure 23. These two signals are independently
programmed using the registers in Table 11. SPOL is the start
polarity for the signal, and TOG1 and TOG2 are the first and
second toggle positions of the pulse. Both signals are active low
and should be programmed accordingly.
A separate pattern for CLPOB and PBLK can be programmed
for each V-sequence. As described in the Vertical Timing
Generation section, several V-sequences can be created, each
containing a unique pulse pattern for CLPOB and PBLK.
Figure 46 shows how the sequence change positions divide the
readout field into regions. A different V-sequence can be
assigned to each region, allowing the CLPOB and PBLK signals
to change with each change in the vertical timing. Unused CLPOB
and PBLK toggle positions should be set to 8191.
CLPOB and PBLK Masking Area
The AD9923A allows the CLPOB and/or PBLK signals to be
disabled during certain lines in the field without changing the
existing CLPOB and/or PBLK pattern settings.
To use CLPOB masking, the CLPMASKSTART and CLPMASKEND
registers are programmed to specify the starting and ending lines
in the field where the CLPOB patterns are ignored. There are three
sets of CLPMASKSTART and CLPMASKEND registers,
allowing up to three CLPOB masking areas to be created.
CLPOB masking registers are not specific to a given V-sequence;
they are active for any existing field of timing. To disable the
CLPOB masking feature, set these registers to the maximum
value, 0xFFF (default value).
To use PBLK masking, the PBLKMASKSTART and
PBLKMASKEND registers are programmed to specify the
starting and ending lines in the field where the PBLK patterns
are ignored. There are three sets of PBLKMASKSTART and
PBLKMASKEND registers, allowing the creation of up to three
PBLK masking areas.
PBLK masking registers are not specific to a given V-sequence;
they are active for any existing field of timing. To disable the
PBLK masking feature, set these registers to the maximum
value, 0xFFF (default value).
Table 11. CLPOB and PBLK Pattern Registers
Register
Length (Bits)
Range
Description
CLPOBPOL
1
High/low
Starting polarity of CLPOB for each V-sequence
PBLKPOL
1
High/low
Starting polarity of PBLK for each V-sequence
CLPOBTOG1
13
0 to 8191 pixel location
First CLPOB toggle position within the line for each V-sequence
CLPOBTOG2
13
0 to 8191 pixel location
Second CLPOB toggle position within the line for each V-sequence
PBLKTOG1
13
0 to 8191 pixel location
First PBLK toggle position within the line for each V-sequence
PBLKBTOG2
13
0 to 8191 pixel location
Second PBLK toggle position within the line for each V-sequence
CLPMASKSTART
12
0 to 4095 line location
CLPOB masking area—starting line within the field (maximum of three areas)
CLPMASKEND
12
0 to 4095 line location
CLPOB masking area—ending line within the field (maximum of three areas)
PBLKMASKSTART
12
0 to 4095 line location
PBLK masking area—starting line within the field (maximum of three areas)
PBLKMASKEND
12
0 to 4095 line location
PBLK masking area—ending line within the field (maximum of three areas)
3
2
1
HD
CLPOB
PBLK
PROGRAMMABLE SETTINGS:
1START POLARITY (CLAMP AND BLANK REGIONS ARE ACTIVE LOW).
2FIRST TOGGLE POSITION.
3SECOND TOGGLE POSITION.
ACTIVE
ACTIVE
Figure 23. Clamp and Preblank Pulse Placement



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com