| 数据搜索系统,热门电子元器件搜索 |
|
BQ40Z50-R2 数据表(PDF) 17 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ40Z50-R2 数据表(HTML) 17 Page - Texas Instruments |
|
17 / 55 page ![]() 7.29 Instruction Flash (continued) Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT IFLASHERASE Flash-erase current TA = –40°C to 85°C 15 mA 7.30 Data Flash Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Data retention 10 Years Flash programming write cycles 20000 Cycles tPROGWORD Word programming time TA = –40°C to 85°C 40 µs tMASSERASE Mass-erase time TA = –40°C to 85°C 40 ms tPAGEERASE Page-erase time TA = –40°C to 85°C 40 ms IFLASHREAD Flash-read current TA = –40°C to 85°C 1 mA IFLASHWRITE Flash-write current TA = –40°C to 85°C 5 mA IFLASHERASE Flash-erase current TA = –40°C to 85°C 15 mA 7.31 OLD, SCC, SCD1, SCD2 Current Protection Thresholds Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VOLD OLD detection threshold voltage range VOLD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –16.6 –100 mV VOLD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –8.3 –50 ΔVOLD OLD detection threshold voltage program step VOLD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –5.56 mV VOLD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –2.78 VSCC SCC detection threshold voltage range VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 44.4 200 mV VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 22.2 100 ΔVSCC SCC detection threshold voltage program step VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 22.2 mV VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 11.1 VSCD1 SCD1 detection threshold voltage range VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –44.4 –200 mV VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –22.2 –100 ΔVSCD1 SCD1 detection threshold voltage program step VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –22.2 mV VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –11.1 VSCD2 SCD2 detection threshold voltage range VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –44.4 –200 mV VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –22.2 –100 www.ti.com BQ40Z50-R2 SLUSCS4C – JUNE 2017 – REVISED APRIL 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 17 Product Folder Links: BQ40Z50-R2 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |