37 / 226 page ![]() ST7FOXF1, ST7FOXK1, ST7FOXK2 Supply, reset and clock management 37/226 Case 2 Switching from AWU RC to internal RC 1. Reset the RC/AWU bit to enable the internal RC oscillator 2. Using a 4-bit counter, wait until 8 internal RC cycles have elapsed. The counter is running on internal RC clock. 3. Wait till the AWU_FLAG is cleared (1AWU RC cycle) and the RC_FLAG is set (2 RC cycles) 4. The switch to the internal RC clock is made at the positive edge of the internal RC clock signal 5. Once the switch is made, the AWU RC is stopped Note: 1 When the internal RC is not selected, it is stopped so as to save power consumption. 2 When the internal RC is selected, the AWU RC is turned on by hardware when entering Auto wakeup from Halt mode. 3 When the external clock is selected, the AWU RC oscillator is always on. Figure 11. Clock switching Internal RC AWU RC Set RC/AWU Poll AWU_FLAG until set Internal RC Reset RC/AWU Poll RC_FLAG until set AWU RC |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|