30 / 50 page ![]() Rev. 1 | Page 30 of 50 | www.onsemi.com Table X. Register Map (Continued) Address Name Default Value Description 3C GPIO4 Event Mask 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO4 being asserted. 3D GPIO5 Event Mask 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO5 being asserted. 3E GPIO6 Event Mask 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to GPIO6 being asserted. 40 Local Temp Fault Action 08h Configures the operation of INT, CFAULT, etc. for a Local Temp fault (internal temperature sensor). 41 Remote 1 Temp Fault Action 08h Configures the operation of INT, CFAULT, etc. for a Remote 1 Temp fault (D1 Temperature Sensor). 42 Remote 2 Temp Fault Action 08h Configures the operation of INT, CFAULT, etc. for a Remote 2 Temp fault (D2 Temperature Sensor). 48 Local Temp Cooling Action 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Local Temp event (internal temperature sensor). 49 Remote 1 Temp Cooling Action 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Remote 1 Temp event (D1 temperature sensor). 4A Remote 2 Temp Cooling Action 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a Remote 2 Temp event (D2 temperature sensor). 50 AIN0 Behavior 00h Configures the operation of INT, CFAULT, etc. for a fault on Analog Channel 0. 51 AIN1 Behavior 00h Configures the operation of INT, CFAULT, etc. for a fault on Analog Channel 1. 58 AIN0 Event Mask 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault on Channel 0. 59 AIN1 Event Mask 00h Enables/disables FAN 1 and/or FAN 2 alarm/hot-plug speed in response to a fault on Channel 1. 60 Fan 1 Minimum/Alarm Speed FFh Contains the Minimum/Alarm speeds for Fan 1. 61 Fan 2 Minimum/Alarm Speed FFh Contains the Minimum/Alarm speeds for Fan 2. 68 Fan 1 Configuration 2Fh Configures hot-plug speed, PWM and tach frequency. 69 Fan 2 Configuration 2Fh Configures hot-plug speed, PWM and tach frequency. 70 Fan 1 Tach Value 00h Contains the measured value from the FAN 1 tachometer output. 71 Fan 2 Tach Value 00h Contains the measured value from the FAN 2 tachometer output. 78 Fan 1 Tach High Limit FFh Contains the high limit for FAN 1 tachometer measurement. 79 Fan 2 Tach High Limit FFh Contains the high limit for FAN 2 tachometer measurement. 80 Local Temp TMIN ??h Defines the starting temperature for the fan when controlled by the local temperature channel, under Automatic Fan Speed Control. 81 Remote 1 Temp TMIN ??h Defines the starting temperature for the fan when controlled by the Remote 1 temperature channel, under Automatic Fan Speed Control. (D1 Temp Sensor). 82 Remote 2 Temp TMIN ??h Defines the starting temperature for the fan when controlled by the Remote 2 temperature channel, under Automatic Fan Speed Control. (D2 Temp Sensor). 88 Local Temp TRANGE/THYST 51h This register programs the control range for the local tempera- ture control loop. It also defines the amount of temperature hysteresis applied to the loop. 89 Remote 1 Temp TRANGE/THYST 51h This register programs the control range for the Remote 1 temperature control loop. It also defines the amount of tem- perature hysteresis applied to the loop. ADM1029 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |