39 / 50 page ![]() Rev. 1 | Page 39 of 50 | www.onsemi.com ADM1029 Register 80h, 81h, 82h – Temp x * TMIN (Power-On Default 001??000) Bit Name R/W Description <7:0> Temp x * TMIN R/W This register contains the minimum temperature value for automatic fan speed control based on the Temp x * temperature. On power-up Pin 18 is sampled by the ADC to determine the default value for Temp x * TMIN. If Pin 18 is strapped to GND or VCC, this register defaults to 32°C, but Automatic Fan Speed Control is disabled. There are eight strappable options on Pin 18. These options are used to set Temp x * TMIN and the Install bit in the Config Register (Reg 01h, Bit 0). The options are as follows: ADC MSBs R1 R2 Install Temp x * TMIN 111 0 ∞ 1 Disabled 101 18 kΩ 82 kΩ 1 48°C 110 22 kΩ 47 kΩ 1 40°C 100 12 kΩ 15 kΩ 1 32°C 011 15 kΩ 12 kΩ 0 32°C 010 47 kΩ 22 kΩ 0 40°C 001 82 kΩ 18 kΩ 0 48°C 000 ∞ 0 0 Disabled *“x” denotes the number of the temperature channel. Register 80h is for the Local temperature channel, 81h is for Remote 1 Temp (D1), 82h is for Remote 2 Temp (D2). Register 88h, 89h, 8Ah Temp x * TRANGE/THYST (Power-On Default 51h) Bit Name R/W Description <3:0> Temp x * TRANGE R/W This nibble contains the temperature range over which automatic fan speed control operates based on the Temp x * measured temperature. Only a limited number of temperature ranges are supported as follows: Bits <3:0> TRANGE 0000 5°C 0001 10°C 0010 20°C 0011 40°C 0100 80°C <7:4> Temp x * THYST R/W This nibble allows programmability of the Hysteresis level around the temperature at which the fan being controlled by Temp x * will switch on in automatic fan speed control mode. Values from 0°C to 15°C are possible. If a value other than 0°C is programmed as a Hysteresis value, the fan will switch on when Temp x* goes above TMIN, but will remain on until Temp x * falls below TMIN–THYST. Between TMIN–THYST and TMIN the fan will run at the programmed minimum pulsewidth in the Fan x * Speed 1 register. *“x” denotes the number of the temperature channel. Register 88h is for the Local temperature channel , 89h is for Remote 1 Temp (D1), 8Ah is for Remote 2 Temp (D2). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |