| 数据搜索系统,热门电子元器件搜索 |
|
E2000 数据表(PDF) 85 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
E2000 数据表(HTML) 85 Page - Intel Corporation |
|
85 / 104 page ![]() Datasheet 85 Thermal Specifications and Design Considerations 5.4.2 PECI Specifications 5.4.2.1 PECI Device Address The PECI device address for the socket is 30h. For more information on PECI domains, refer to the Platform Environment Control Interface Specification. 5.4.2.2 PECI Command Support PECI command support is covered in detail in the Platform Environment Control Interface Specification. Refer to this document for details on supported PECI command function and codes. 5.4.2.3 PECI Fault Handling Requirements PECI is largely a fault tolerant interface, including noise immunity and error checking improvements over other comparable industry standard interfaces. The PECI client is as reliable as the device that it is embedded in, and thus given operating conditions that fall under the specification, the PECI will always respond to requests and the protocol itself can be relied upon to detect any transmission failures. There are, however, certain scenarios where the PECI is know to be unresponsive. Prior to a power on RESET# and during RESET# assertion, PECI is not ensured to provide reliable thermal data. System designs should implement a default power-on condition that ensures proper processor operation during the time frame when reliable data is not available via PECI. To protect platforms from potential operational or safety issues due to an abnormal condition on PECI, the Host controller should take action to protect the system from possible damaging states. It is recommended that the PECI host controller take appropriate action to protect the client processor device if valid temperature readings have not been obtained in response to three consecutive gettemp()s or for a one second time interval. The host controller may also implement an alert to software in the event of a critical or continuous fault condition. 5.4.2.4 PECI GetTemp0() Error Code Support The error codes supported for the processor GetTemp() command are listed in Table 32. § § Table 32. GetTemp0() Error Codes Error Code Description 8000h General sensor error 8002h Sensor is operational, but has detected a temperature below its operational range (underflow). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |