| 数据搜索系统,热门电子元器件搜索 |
|
TNETX4080GGP 数据表(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETX4080GGP 数据表(HTML) 34 Page - Texas Instruments |
|
34 / 64 page ![]() TNETX4080 ThunderSWITCH II™ 8-PORT 10-/100-MBIT/S ETHERNET™ SWITCH SPWS050A – AUGUST 1998 – REVISED NOVEMBER 1998 34 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 Table 10. LED Status Bit Definitions and Shift Order ORDER NAME FUNCTION slast = 0 slast = 1 NAME FUNCTION 1st–12th 11th–22nd SW0–SW11 Software LEDs 0–11. These allow additional software-controlled status to be displayed. These 12 LEDs reflect the values of bits 0–11 of the swied field in LEDControl at the moment that the LED interface samples them. If this occurs between writes to the most significant and least significant bytes of LEDControl, these values appear on the LEDs, separated by 1/16th of a second. 13th–21st 1st–9th P00–P08 Port status LEDs 0–8. These nine LEDs indicate the status of ports 0–8, in this order (port 0 is output first). Note that port 9 (management port) does not have an LED. The transmit multicast content of these bits can be controlled by the txais bit in LEDControl. Note that IEEE Std 802.3x pause frames never appear on the LEDs as port activity. The port’s LED toggles each 1/16th of a second if there was any frame traffic (other than pause frames) on the port during the previous 1/16th of a second. 22nd 10th C08 Port 8 collision LED. LED is extinguished if the port 8 is not in PMA mode. It indicates the collisions on port 8 and toggles each 1/16th of a second if there is a collision on the port during the previous 1/16th of a second. 23rd 23rd FLOW Flow control. LED is on when the internal flow control is enabled and active. Active means that flow control was asserted during the previous 1/16th of a second. 24th 24th FAULT Fault. LED indicates: – the EEPROM CRC was invalid. – an external DRAM parity error has occurred. – the FITLED in LEDControl has been set. The CRC and parity error indications are cleared by hardware reset (pin or DIO). The CRC error indication also is cleared by setting load to 1. The parity error indication also is cleared by setting start to 1. lamp test When the device is in the hardware reset state, LED_DATA is driven low and LED_CLK runs continuously. This causes all LEDs to be illuminated and serves as a lamp test function. multi-LED display The LED interface is intended to provide the lowest-cost display with a single multifunction LED per port. In systems requiring a full-feature display using multiple LEDs per port, this is achieved by driving the LEDs directly from the PHY signals. RDRAM interface The TNETX4080 requires the use of external memory devices to retain frame data during switching operations. The high bandwidth requirements of gigabit-per-second Ethernet switching are met using a concurrent RDRAM interface (see Rambus Layout Guide, literature number DL0033). Each RDRAM interface operates at 600-Mbit/pin/s and is intended for use with 16-/18-/64-/72-Mbit/s concurrent RDRAMs with access times of 50 ns. The TNETX4080 automatically determines the word length of the RDRAMs during initialization and performs parity checks if 9-bit memories are in use. A maximum of 16 RDRAM devices of differing organizations can be attached to any one RDRAM interface. Multiple devices must be daisy-chained together via their SIN and SOUT pins during initialization (see Figure 5). All RDRAMs in a given system must be of the same type. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |