97 / 142 page ![]() M24LR04E-R Command codes Doc ID 022208 Rev 5 97/142 Response parameter: ● No parameter. Response parameter: ● Error code as Error_flag is set: – 11h: the specified block is already locked and thus cannot be locked again – 14h: the specified block was not successfully locked . When configured in the RF busy mode, the RF WIP/BUSY pin is tied to 0 from the SOF that starts the Lock DSFID command to the end of the M24LR04E-R response. When configured in the RF write in progress mode, the RF WIP/BUSY pin is tied to 0 for the duration of the internal write cycle (from the end of a valid Lock DSFID command to the beginning of the M24LR04E-R response). Table 68. Lock DSFID response format when Error_flag is set Response SOF Response_flags Error code CRC16 Response EOF 8 bits 8 bits 16 bits Figure 64. Lock DSFID frame exchange between VCD and M24LR04E-R VCD SOF Lock DSFID request EOF M24LR04E-R <-t1-> SOF Lock DSFID response EOF Lock sequence when error M24LR04E-R <----------------- Wt ------------> SOF Lock DSFID response EOF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|