71 / 182 page ![]() ! 58 The PC ignores all momentary power interruptions if the interruption lasts no longer than 10 ms. If the interruption lasts between 10 and 25 ms, the interrup- tion may or may not be detected. If the supply voltage drops below 85% of the rated voltage for longer than 25 ms (less for the DC Power Supply Unit), a power interruption detection signal is output and program execution is halted. If power is not restored within 10 ms (the power retention time) after the power interruption detection signal is output, the PC stops operating and all outputs are turned OFF. If after power interruption detection, power is restored within a period defined as the momentary power interruption time (default value: 0 ms), the CPU will re- sume operation. If the momentary power interruption time elapses and power has not been restored, the CPU will begin execution of the power OFF interrupt program if one has been programmed. The CPU stops operating after the lapse of the power retention time (10 ms). Note The momentary power interruption time can be set to between 0 and 10 ms. For details, refer to the CVSS Operation Manuals. Caution If a C500 Expansion I/O Rack is connected to the PC, the momentary power in- terruption time setting is not effective and a power interruption of any length will trigger shut down processing. Automatic Recovery Operation is resumed automatically when the voltage is restored to more than 85% of the rated value. 3-4-6 Current Consumption The Power Supply Units are limited in the total current they can supply to Units on the Racks. The following table shows the maximum current available on a Rack for either model of Power Supply Unit. The available current shown in the table is in addition to the current consumed by the Backplane, Power Supply Unit, CPU, I/O Control Unit, I/O Interface Unit, and Peripheral Devices. Rack CV500-PS221/211 CVM1-PA208 CPU Rack CV500 or CVM1-CPU01-EV2 9.8 A max. 5.8 A max. CV1000, CV2000, CVM1-CPU11-EV2, or CVM1-CPU21-EV2 9.4 A max. 5.4 A max. Expansion CPU Rack 11 A max. 7 A max. Expansion I/O Rack 11 A max. 7 A max. Calculate the current requirements for the Units on each Rack by adding up the current consumption of each Unit mounted, excluding the Power Supply Unit, CPU, I/O Control Unit, I/O Interface Unit, Remote I/O Slave Units, and Peripher- al Devices (the power requirements for these Units have already been allowed for). The total must not exceed the limit given above for the Rack. The current consumption for the Expansion I/O Rack does not include the cur- rent consumed by peripheral devices. The current consumed by peripheral devices attached to the Expansion I/O Rack must be included when calculating the total current consumption. Power Supply Units Section 3-4 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |