| 数据搜索系统,热门电子元器件搜索 |
|
3G5A2-RPT01-PE 数据表(PDF) 48 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
3G5A2-RPT01-PE 数据表(HTML) 48 Page - Omron Electronics LLC |
|
48 / 182 page ![]() 35 CV500-PS221/CVM1-PA208 POWER Indicator Lights when power is supplied. Terminals for external connections START input RUN output Connect a 100 to 120-VAC or 200 to 240-VAC power source. Short the (LG) terminal to the (GR) terminal to improve noise immunity and prevent electric shock. AC input Ground this terminal at a resistance of less than 100 W to prevent electric shock. Use an independent ground not shared with other equipment. These terminals are short-circuit at the factory. Remove the sort-circuit bracket to allow enabling and disab- ling of the PC with an external signal (input: 24 VDC,10 mA). Normally, leave them short-circuited. These ter- minals are used on CPU Racks only. These terminals are turned ON during RUN operation. Maximum Switching Capacity: 250 VAC: 2 A (resistive load, cos f = 1) 250 VAC: 0.5 A (inductive load, cos f = 0.4) 24 VDC: 2 A NC NC CV500-PS211 POWER Indicator Lights when power is supplied. Terminals for external connections START input RUN output Connect a 24-VDC power source. Short the (LG) terminal to the (GR) terminal to improve noise immunity and prevent electric shock. DC input Ground this terminal at a resistance of less than 100 W to prevent electric shock. Use an independent ground not shared with other equipment. These terminals are short-circuited at the factory. Remove the sort-circuit bracket to allow enabling and disab- ling of the PC with an external signal (input: 24 VDC, 10 mA). Normally, leave them short-circuited. These ter- minals are used on CPU Racks only. These terminals are turned ON during RUN operation. Maximum Switching Capacity: 250 VAC: 2 A (resistive load, cos f = 1) 250 VAC: 0.5 A (inductive load, cos f = 0.4) 24 VDC: 2 A Maximum Switching Capacity when Meeting EC Directives (Low-voltage Directives): 24 VDC: 2 A NC NC Note When complying with EC Directives (low voltage), use rein- forced insulation or double insulation on the DC power supply. Rack Components Section 2-3 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |