| 数据搜索系统,热门电子元器件搜索 |
|
3G5A2-RPT01-PE 数据表(PDF) 35 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
3G5A2-RPT01-PE 数据表(HTML) 35 Page - Omron Electronics LLC |
|
35 / 182 page ![]() 22 Configuration Limits The following two tables indicate limits on the system configuration. The first table indicates limits for the basic System. The second table indicates limits for Remote I/O Systems. Basic System Item CV500 or CVM1-CPU01-EV2 CV1000 or CVM1-CPU11-EV2 CV2000 or CVM1-CPU21-EV2 Number of I/O points 512 points (32 words) 1,024 points (64 words) 2,048 points (128 words) Number of connectable Expansion CPU Racks 1 Number of connectable Expansion I/O Racks 7 (6 if an Expansion CPU Rack is also used) Number of I/O slots on CPU Rack 3/5/10 Number of I/O slots on Expansion CPU Rack 11 Number of I/O slots on Expansion I/O Rack 4/6/11 Remote I/O Systems Item SYSMAC BUS/2 (see note 2) SYSMAC BUS CV500 or CVM1-CPU01 -EV2 CV1000, CV2000, CVM1-CPU11 -EV2, or CVM1-CPU21 -EV2 CV500 or CVM1-CPU01 -EV2 CV1000, CV2000, or CVM1-CPU11 -EV2 CVM1-CPU21 -EV2 Limits per PC No. of remote I/O points 1,024 pts (64 words) 2,048 pts (128 words) 512 pts (32 words) 1,024 pts (64 words) 2,048 pts (128 words) No. of Remote Masters 2 4 4 8 No. of Slave Racks --- --- 8 16 Limits No. of Slaves (see 1) 58M Slaves: 8 Units 2 8 per Remote ( note 1) 122M Slaves: 4 Units Remote I/O 54MH Slaves: 4 Units I/O Master Unit No. of remote I/O points 58M Slaves: 464 input and 464 output 512 pts (32 words) 122M Slaves: 976 input and 976 output 54MH Slaves: 432 input and 432 output Combined No. of Slaves, I/O Link Units, Optical I/O Units, and I/O Terminals --- 64 (optical) 32 (wired) Expansion I/O Backplanes CV500-BI112/062/042 C500-BI081/051 Note 1. 58M Slaves are counted as one Unit and 122M and 54 MH Slaves are counted as two Units in figuring the total of eight connectable Units. 58M, 122M, and 54MH classifications are set with a switch on the Slave. 2. A SYSMAC BUS/2 Slave must be designated “54MH” to use READ(190)/WRIT(191) for Special I/O Units mounted to it. These instruc- tions cannot be used for SYSMAC BUS Slaves regardless. System Configuration Section 2-1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |