16 / 36 page ![]() REV. A –16– ADMC(F)341 PWMCHA = PWMCHB PWMTM PWMTM AH AL BH BL 2 PWMDT 2 PWMDT CH CL Figure 9. An Example of PWM Signals Suitable for ECM Control. PWMCHA = PWMCHB, BH/BL are a Crossover Pair. AL, BH, CH, and CL Outputs are Disabled. Operation is in Single Update Mode. Gate Drive Unit: PWMGATE Register The gate drive unit of the PWM controller adds features that simplify the design of isolated gate drive circuits for PWM inverters. If a transformer-coupled power device gate drive amplifier is used, the active PWM signal must be chopped at a high frequency. The PWMGATE register allows the programming of this high frequency chopping mode. The chopped active PWM signals may be required for the high side drivers only, for the low side drivers only, or for both the high side and low side switches. Therefore, independent control of this mode for both high side and low side switches is included with two separate control bits in the PWMGATE register. Typical PWM output signals with high frequency chopping enabled on both high side and low side signals are shown in Figure 10. Chopping of the high side PWM outputs (AH, BH and CH) is enabled by setting Bit 8 of the PWMGATE register. Chopping of the low side PWM outputs (AL, BL, and CL) is enabled by setting Bit 9 of the PWMGATE register. The high chopping frequency is controlled by the 8-bit word (GDCLK) written to Bits 0 to 7 of the PWMGATE register. The period and the frequency of this high frequency carrier are: T GDCLK t CHOP CK =× ()+ []× 41 f f GDCLK CHOP CLKOUT = ×+ () [] 41 The GDCLK value may range from 0 to 255, corresponding to a programmable chopping frequency rate from 19.5 kHz to 5 MHz for a 20 MHz CLKOUT rate. The gate drive features must be programmed before operation of the PWM controller and typically are not changed during normal operation of the PWM control- ler. Following a reset, by default, all bits of the PWMGATE register are cleared so that high frequency chopping is disabled. PWMTM PWMTM [4 (GDCLK+1)] 2 PWMDT 2 PWMDT PWMCHA PWMCHA AH AL Figure 10. Typical PWM Signals With High Frequency Gate Chopping Enabled on Both High Side and Low Side Switches. (GDCLK is the Integer Equivalent of the Value in Bits 0 to 7 of the PWMGATE Register.) PWM Shutdown In the event of external fault conditions, it is essential that the PWM system be instantaneously shut down. Two methods of sensing a fault condition are provided by the ADMC(F)341. For the first method, a low level on the PWMTRIP pin initiates an instantaneous, asynchronous (independent of DSP clock) shutdown of the PWM controller. This places all six PWM outputs in the OFF state, disables the PWMSYNC pulse and associated interrupt signal, and generates a PWMTRIP inter- rupt signal. The PWMTRIP pin has an internal pull-down resistor so that even if the pin becomes disconnected, the PWM outputs will be disabled. The state of the PWMTRIP pin can be read from Bit 0 of the SYSSTAT register. The second method for detecting a fault condition is through the ISENSE pins of the analog block of the ADMC(F)341. When the voltage at any of the ISENSE pins exceeds the trip threshold (high or low), or the ISENSE pin is in high impedance (floating), PWMTRIP will be internally pulled low. The negative edge of the internal PWMTRIP will generate a shutdown in the same manner as a negative edge on pin PWMTRIP. It is possible through software to initiate a PWM shutdown by writing to the 1-bit read/write PWMSWT register (0x2061). Writing to this bit generates a PWM shutdown in a manner identical to the PWMTRIP or I SENSE pins. Following a PWM shutdown, it is possible to determine if the shutdown was gener- ated from hardware or software by reading the same PWMSWT register. Reading this register also clears it. Restarting the PWM after a fault condition is detected requires clearing the fault and reinitializing the PWM. Clearing the fault requires PWMTRIP to return to a high state and I SENSE to re- turn to a voltage in the ISENSE trip level range. After the fault has been cleared, the PWM can be restarted by writing to registers PWMTM, PWMCHA, PWMCHB, and PWMCHC. After the fault is cleared and the PWM registers are initialized, internal timing of the three-phase timing unit will resume, and the new duty cycle values will be latched on the next rising edge of PWMSYNC. PWM Registers The configuration of the PWM registers is described in Figures 23, 24, and 27. The parameters of the PWM block are tabu- lated in Table V. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |