| 数据搜索系统,热门电子元器件搜索 |
|
L9663 数据表(PDF) 41 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9663 数据表(HTML) 41 Page - STMicroelectronics |
|
41 / 104 page ![]() DocID028693 Rev 1 41/104 L9663 Satellite interface 103 Master Mode Short to battery test – Enable PSI1 channel – Wait for a 512 μs time in order to reach steady state condition (short to ground and overcurrent masked in this phase) – Check psi1_stb='0': in case psi1_stb='1' the fault flag is asserted and the channel 1 is not involved in the following tests – Switch off PSI1 channel and switch on IXCT pull down current for a 128 μs time on PSI1 interface – Once PSI5 line is supposed to be discharged (128 μs time elapsed), pull-down current is switched OFF – Enable PSI2 channel – Repeat the above flow for PSI2 channel X coupling test phase 1 (only if channel 1 was not excluded in previous short to battery test) – Enable PSI1 channel, PSI2 channel switched off – Wait for 512 μs time in order to reach steady state condition and allow PSI under voltage filter time to elapse (short to ground and overcurrent masked in this phase) – Check psi1_uv='0' and psi2_uv='1': in case of psi1_uv='1' a short to GND on PSI1 is detected while in case psi2_uv='0' a cross coupling is detected and XCT2_R bit is set (h) – Switch off PSI1 channel and switch on IXCT pull down current for a 128 μs time – Once PSI5 line is supposed to be discharged (128 μs time elapsed), pull-down current is switched off. X coupling test phase 2 (only if channel 2 was not excluded in previous short to battery test) – Enable PSI2 channel, PSI1 channel switched off – Wait for 512us time in order to reach steady state condition and allow PSI under voltage filter time to expire (short to ground and overcurrent masked in this phase) – Check psi2_uv='0' and psi1_uv='1': in case of psi2_uv='1' a short to GND on PSI2 is detected while in case psi1_uv='0' a cross coupling is detected and XCT1_R bit is set – Switch off PSI2 channel and switch on IXCT pull down current for a 128 μs time – Once PSI5 line is supposed to be discharged (128 μs time elapsed), pull-down current is switched off Short to battery test in master mode is executed in two phases for the two channels to avoid enabling simultaneously PSIx interfaces and avoid overloading ECU supply line. Cross coupling test in master mode stops automatically when the time required by this test is elapsed. Cross coupling test in slave mode can be stopped with "Abort cross coupling test" command; only in this case, the flag "cross-coupling test aborted" is not set, because this is not a faulty condition. h. Cross coupling test flags swapped in master mode, see errata n.1830, Section 7: Errata. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |