13 / 56 page ![]() 90 Remote DMA (Continued) REMOTE WRITE A Remote Write transfer is used to move a block of data from the host into local buffer memory The Remote DMA will read data from the IO port and sequentially write it to local buffer memory beginning at the Remote Start Address The DMA Address will be incremented and the Byte Coun- ter will be decremented after each transfer The DMA is terminated when the Remote Byte Count Register reaches a count of zero REMOTE READ A Remote Read transfer is used to move a block of data from local buffer memory to the host The Remote DMA will sequentially read data from the local buffer memory begin- ning at the Remote Start Address and write data to the IO port The DMA Address will be incremented and the Byte Counter will be decremented after each transfer The DMA is terminated when the Remote Byte Count Register reach- es zero REMOTE DMA WRITE Setting PRQ Using the Remote Read Under certain conditions the NIC’s bus state machine may issue MWR and PRD before PRQ for the first DMA trans- fer of a Remote Write Command If this occurs this could cause data corruption or cause the remote DMA count to be different from the main CPU count causing the system to ‘‘lock up’’ To prevent this condition when implementing a Remote DMA Write the Remote DMA Write command should first be preceded by a Remote DMA Read command to insure that the PRQ signal is asserted before the NIC starts its port read cycle The reason for this is that the state machine that asserts PRQ runs independently of the state machine that controls the DMA signals The DMA machine assumes that PRQ is asserted but actually may not be To remedy this situation a single Remote Read cycle should be inserted before the actual DMA Write Command is given This will ensure that PRQ is asserted when the Remote DMA Write is subsequently executed This single Remote Read cycle is called a ‘‘dummy Remote Read’’ In order for the dummy Remote Read cycle to operate correctly the Start Address should be programmed to a known safe location in the buff- er memory space and the Remote Byte Count should be progammed to a value greater than 1 This will ensure that the master read cycle is performed safely eliminating the possiblity of data corruption Remote Write with High Speed Buses When implementing the Remote DMA Write solution in pre- vious section with high speed buses and CPU’s timing problems may cause the system to hang Therefore addi- tional considerations are required The problem occurs when the system can execute the dum- my Remote Read and then start the Remote Write before the NIC has had a chance to execute the Remote Read If this happens the PRQ signal will not get set and the Re- mote Byte Count and Remote Start Address for the Remote Write operation could be corrupted This is shown by the hatched waveforms in the timing diagram below The execu- tion of the Remote Read can be delayed by the local DMA operations (particularly during end-of-packet processing) To ensure the dummy Remote Read does execute a delay must be inserted between writing the Remote Read Com- mand and starting to write the Remote Write Start Address (This time is designated in figure below by the delay arrows) The recommended method to avoid this problem is after the Remote Read command is given to poll both bytes of the Current Remote DMA Address Registers When the ad- dress has incremented PRQ has been set Software should recognize this and then start the Remote Write An additional caution for high speed systems is that the polling must follow guidelines specified at the end of Sec- tion 13 That is there must be at least 4 bus clocks between chip selects (For example when BSCK e 20 MHz then this time should be 200 ns) The general flow for executing a Remote Write is 1 Set Remote Byte Count to a value l1 and Remote Start Address to unused RAM (one location before the transmit start address is usually a safe location) TLF8582 – 96 Timing Diagram for Dummy Remote Read Note The dashed lines indicate incorrect timing 13 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |