ADE7758 数据表(PDF) 35 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7758 数据表(HTML) 35 Page - Analog Devices |
|
35 / 68 page ![]() ADE7758 Rev. A | Page 35 of 68 Phase A, Phase B, and Phase C zero crossings are, respectively, included when counting the number of half-line cycles by setting ZXSEL[0:2] bits (Bit 3 to Bit 5) in the LCYCMODE register. Any combination of the zero crossings from all three phases can be used for counting the zero crossing. Only one phase should be selected at a time for inclusion in the zero crossings count during calibration (see the Calibration section). The number of zero crossings is specified by the LINECYC register. LINECYC is an unsigned 16-bit register. The ADE7758 can accumulate active power for up to 65535 combined zero crossings. Note that the internal zero crossing counter is always active. By setting the LWATT bit, the first energy accumulation result is therefore incorrect. Writing to the LINECYC register when the LWATT bit is set resets the zero-crossing counter, thus ensuring that the first energy accumulation result is accurate. At the end of an energy calibration cycle, the LENERGY bit (Bit 12) in the STATUS register is set. If the corresponding mask bit in the interrupt mask register is enabled, the IRQ output also goes active low; thus, the IRQ can also be used to signal the end of a calibration. Because active power is integrated on an integer number of half line cycles in this mode, the sinusoidal component is reduced to 0. This eliminates any ripple in the energy calculation. Therefore, total energy accumulated using the line-cycle accumulation mode is () t IRMS VRMS t E × × = (14) where t is the accumulation time. Note that line cycle active energy accumulation uses the same signal path as the active energy accumulation. The LSB size of these two methods is equivalent. Using the line cycle accumula- tion to calculate the kWh/LSB constant results in a value that can be applied to the WATTHR registers when the line accumulation mode is not selected (see the Calibration section). REACTIVE POWER CALCULATION A load that contains a reactive element (inductor or capacitor) produces a phase difference between the applied ac voltage and the resulting current. The power associated with reactive elements is called reactive power and its unit is VAR. Reactive power is defined as the product of the voltage and current waveforms when one of these signals is phase shifted by 90°. Equation 17 gives an expression for the instantaneous reactive power signal in an ac system when the phase of the current channel is shifted by +90°. () ( θ ω = – sin 2 t V t v ) (15) () () () ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ π + ω = ′ ω = 2 sin 2 sin 2 t I t i t I t i (16) where V = rms voltage, I = rms current, θ = total phase shift caused by the reactive elements in the load. Then the instantaneous reactive power q(t) can be expressed as ( ) ( ) ( ) () ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ π θ ω ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ π θ = ′ × = 2 – – 2 cos – 2 – – cos t VI VI t q t i t v t q where ( ) t i′ is the current waveform phase shifted by 90°. Note that q(t) can be rewritten as ( ) ( )( θ ω ) + θ = – 2 sin sin t I V VI t q (17) The average reactive power over an integral number of line cycles (n) is given by the expression in Equation 18. () ( ) ∫ × × = = nT I V dt t q nT Q 0 θ sin 1 (18) where T is the period of the line cycle. Q is referred to as the average reactive power. The instantaneous reactive power signal q(t) is generated by multiplying the voltage signals and the 90° phase-shifted current in each phase. The dc component of the instantaneous reactive power signal in each phase (A, B, and C) is then extracted by a low-pass filter to obtain the average reactive power information on each phase. This process is illustrated in Figure 71. The reactive power of each phase is accumulated in the corresponding 16-bit VAR- hour register (AVARHR, BVARHR, or CVARHR). The input to each reactive energy register can be changed depending on the accumulation mode setting (see Table 17). The frequency response of the LPF in the reactive power signal path is identical to that of the LPF2 used in the average active power calculation (see Figure 65). VRMS × IRMS × sin(φ) θ 00000h CURRENT i(t) = 2 × IRMS × sin(ωt) VOLTAGE v(t) = 2 × VRMS × sin(ωt–θ) INSTANTANEOUS REACTIVE POWER SIGNAL q(t) = VRMS × IRMS × sin(φ) + VRMS × IRMS × sin(2ωt+θ) AVERAGE REACTIVE POWER SIGNAL = VRMS × IRMS × sin(θ) Figure 71. Reactive Power Calculation The low-pass filter is nonideal so the reactive power signal has some ripple. This ripple is sinusoidal and has a frequency equal |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |