20 / 44 page ![]() DA6505.005 11 June 2018 20 (44) STATUS REGISTER (F0HEX) The Status register (F0HEX) contains various status flags. See table 5. The ERDY flag goes low (ERDY=0) during EEPROM read and write operations to indicating EEPROM being busy. After EEPROM operation is finished the ERDY flag returns high (ERDY=1). The FIRSTT and FIRSTP flags are for internal use only. When being high they indicate that the running measurement is the first one after starting the measurements. They are reset right after the first measurement has ended. The RDYT and RDYP flags indicate when unread temperature and pressure results are available at the result registers. Polling status of these two flags can be used to decide when to read out the new measurement results. Reading data from any of the three Pressure result registers (F1…F3HEX) clears the RDYP flag (RDYP=0). Reading data from any of the three Temperature result registers (F4…F6HEX) clears the RDYT flag (RDYT=0). Table 5. Status register (F0HEX) Bit Number Bit Name Description Value Function 7-5 - - 000 - 4 ERDY 0 1 EEPROM busy EEPROM ready 3 FIRSTT 0 1 Not first T measurement First run T measurement 2 FIRSTP 0 1 Not first run P measurement First run P measurement 1 RDYT 0 1 No unread T result available Unread T result available 0 RDYP 0 1 No unread P result available Unread P result available T = temperature, P = pressure PRESSURE MEASUREMENT RESULT REGISTERS (F1…F3HEX) The measurement result of pressure is stored into three read only type Pressure measurement result registers in addresses F1…F3HEX. MSB (most significant byte) is at F1HEX, LSB (least significant byte) at F2HEX and XLSB (extra least significant byte) at F3HEX. If IIR low pass filtering is selected (FILTER<>000 in the Configuration registers) the pressure measurement result registers contain filtered value of measurement results. TEMPERATURE MEASUREMENT RESULT REGISTERS (F4…F6HEX) The measurement result of temperature is stored into three read only type Temperature measurement result registers in addresses F4…F6HEX. MSB (most significant byte) is at F4HEX, LSB (least significant byte) at F5HEX and XLSB (extra least significant byte) at F6HEX. If IIR low pass filtering is selected (FILTER<>000 in the Configuration registers) the temperature measurement result registers contain filtered value of measurement results. TEST INPUT DATA REGISTERS (F7/77…F9/79HEX) The three bytes of Test input data registers (F7/77…F9/79HEX) are for testing purpose only. By the Trim and test register (FA/7AHEX) setting SCALC=1 it is possible to choose taking data for the temperature and pressure result IIR low pass filters from the Test input data registers. This test mode allows testing temperature and pressure result IIR low pass filters with any 24-bit input data. In normal operation (SCALC=0) the input data for the IIR filters are the latest temperature and pressure conversion results. Filtered temperature and pressure results are stored into the Temperature result registers (F4/74…F6/76HEX) and the Pressure result registers (F1/71…F3/73HEX) respectively. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |