10 / 44 page ![]() DA6505.005 11 June 2018 10 (44) FUNCTIONAL DESCRIPTION (continued) Reading measurement results MAS6505 pressure and temperature measurement results are 24-bit unsigned numbers each of which are stored into three 8-bit result registers. The pressure result addresses are MSB byte (F1HEX), LSB byte (F2HEX) and XLSB byte (F3HEX). The temperature result addresses are MSB byte (F4HEX), LSB byte (F5HEX) and XLSB byte (F6HEX). MAS6505 A/D conversion and result status can be monitored from Status register (F0HEX) which contains RDYT and RDYP flags to indicate when there are unread temperature (T) and/or pressure (P) measurement results available in the pressure and temperature result registers. See figure 2 and table 7. The corresponding RDYx (x=T or P) flag is set (1) when a new measurement is ready for a read. Reading the measurement result will clear (0) the corresponding RDYx (x=T or P) flag. The decision when to read measurement results can be made by polling the Status register and waiting until the flag(s) of selected measurement(s) (RDYT and/or RDYP flags) have been set high. This method can be used in both forced and normal modes. In forced mode an another choice is to wait at least maximum A/D conversion time before reading the result. See also figure 3 for Calibrated MAS6505 sensor system measurement flow. In normal mode it is also possible to read results at a rate when new results are expected to be ready. This is possible since MAS6505 has internal A/D conversion result memory buffer. If new result is finished during read of result registers the new value is updated result registers only after the serial bus communication has been released. Important note: In normal mode the results must be always read using incremental read (all three bytes of each result or all six bytes of both results at single read sequence) to maintain A/D conversion data consistency. See table 15 example of the incremental read in chapter 2-wire serial data interface (I2C bus). The incremental read is recommended to be used also in the forced mode. Figure 2. Forced and normal mode measurement and status register RDYT and RDYP flag update timing (T=temperature, P=pressure) T or P . DELAY setting Forced mode temperature or pressure Forced mode temperature and pressure Normal mode temperature or pressure Normal mode temperature and pressure T or P . T P x . time time time RDYT or RDYP flag set RDYT flag set RDYP flag set RDYT or RDYP flag set RDYT or RDYP flag set Measurement start by setting MODE=01 or 10 Measurement start by setting MODE=01 or 10 Measurement start by setting MODE=11 P x . T P x . DELAY setting time RDYT flag set RDYP flag set RDYT flag set RDYP flag set Measurement start by setting MODE=11 T T or P . DELAY setting T or P… ... |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |