| 数据搜索系统,热门电子元器件搜索 |
|
MAS6505 数据表(PDF) 12 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6505 数据表(HTML) 12 Page - Micro Analog systems |
|
12 / 44 page ![]() DA6505.005 11 June 2018 12 (44) FUNCTIONAL DESCRIPTION (continued) Analog front-end and ADC trimming The pressure and temperature sensors are interfaced with analog front-end (AFE) which comprises of a low noise chopper amplifier with 32 selectable gain options from 1x up to 55.8x and an input signal polarity selection. The amplified sensor signal is then fed to input of the delta-sigma ( ΔΣ) analog-to-digital converter (ADC). The input signal range of the ratiometric ADC is ISRADC=1400 mV at the nominal sensor supply voltage VDDS=1.68 V. This corresponds to differential signal ranging from - 700mV to +700mV. The ADC offers eight input offset options with both polarities to adjust to different sensor signals. For the best resolution and to avoid signal clipping the amplifier gain and the ADC offset settings need to be trimmed optimally for both the temperature and the pressure sensor signals. In optimal cases the signal ranges of amplified sensor signals cover maximally the linear input signal range (ISRLIN) of the ADC. The ISRLIN is 10%...90% of the ISR i.e. ISRLIN = 80%*ISR = 1120 mV at VDDS=1.68 V. See further details in chapters AFE AND ADC INPUT SIGNAL RANGE DEFINITIONS and AFE GAIN AND ADC OFFSET SELECTIONS. MAS6505 has individual AFE and ADC trimming settings for both pressure and temperature measurement. The AFE gain and polarity for pressure is trimmed using Pressure gain trim register (FC/7CHEX). See table 8. The corresponding EEPROM storage address is (BC/3CHEX). The AFE gain and polarity for temperature is trimmed using Temperature gain trim register (FD/7DHEX). See table 9. The corresponding EEPROM storage address is (BD/3DHEX). The ADC offsets and polarities for pressure and temperature are trimmed using Temperature and pressure offset trim register (FE/7EHEX). See table 10. The corresponding EEPROM storage address is (BE/3EHEX). Internal clock oscillator MAS6505 has an internal clock oscillator making external clock unnecessary. In the forced mode it is turned on only during the A/D conversions and turned off when the sleep mode is entered. In the normal mode the internal clock oscillator is turned on continuously to run selected measurements periodically. The internal oscillator frequency is factory trimmed to 250 kHz using a 7-bit register. See table 11 for Clock oscillator frequency trim register (FF/7FHEX). The factory trimming value has been stored into EEPROM address (BF/3FHEX). Note: it is recommended to not touch the factory trimming value of the internal clock oscillator. The converter runs from a divided system clock which is 125 kHz. EEPROM memory The 512-bit (64 byte) EEPROM memory is available for storing trimming and calibration data on chip. Six of the EEPROM bytes are reserved for trimming purposes. One byte is for selecting temperature sensor and trimming sensor bridge resistance that is used in sensor bridge resistance based temperature measurements. Three bytes are for trimming AFE gain and ADC offset in the pressure and temperature measurements. Two EEPROM addresses are reserved for storing factory trimming values of EEPROM oscillator and internal clock oscillator. These EEPROM addresses must be left untouched. The remaining 464 bits (58 bytes) in addresses 80/00HEX … B9/39HEX are free for other use such as storing sensor calibration coefficients. See table 1. After power on reset the EEPROM is by default inactive. To use EEPROM (read or write) it needs to be first activated. To prevent accidental overwriting or erasing of the trimming and calibration memory the EEPROM write requires an additional enable setting. These EEPROM functions are controlled using EEPROM control register (ED/6DHEX). See table 2 for EON and EWE bit settings. When activated the EEPROM draws typically 60µA current. To save current the EEPROM should be always disabled after use. See also chapters EEPROM WRITE PROCEDURE and EEPROM READ ONLY PROCEDURE. Calibration MAS6505 performs pressure and temperature measurements resulting raw measurement values. Thus calibrated temperature and pressure reading calculations need to be done outside in the host system by utilizing calibration coefficients that are stored into the EEPROM during sensor calibration procedure. See additional DAE6505 document regarding sensor system calibration. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |