34 / 56 page ![]() ADE7763 Rev. A | Page 34 of 56 ENERGIES SCALING The ADE7763 provides measurements of active and apparent energies. These measurements do not have the same scaling and therefore cannot be compared directly to each other. Table 7. Energies Scaling PF = 1 PF = 0.707 PF = 0 Integrator on at 50 Hz Active Wh Wh × 0.707 0 Apparent Wh × 0.848 Wh × 0.848 Wh × 0.848 Integrator off at 50 Hz Active Wh Wh × 0.707 0 Apparent Wh × 0.848 Wh × 0.848 Wh × 0.848 Integrator on at 60 Hz Active Wh Wh × 0.707 0 Apparent Wh × 0.827 Wh × 0.827 Wh × 0.827 Integrator off at 60 Hz Active Wh Wh × 0.707 0 Apparent Wh × 0.827 Wh × 0.827 Wh × 0.827 CALIBRATING AN ENERGY METER The ADE7763 provides gain and offset compensation for active and apparent energy calibration. Its phase compensation corrects phase error in active and apparent energy. If a shunt is used, offset and phase calibration may not be required. A reference meter or an accurate source can be used to calibrate the ADE7763. When using a reference meter, the ADE7763 calibration output frequency, CF, is adjusted to match the frequency output of the reference meter. A pulse output is only provided for the active energy measurement in the ADE7763. If a reference meter is used to calibrate the VA, then additional code must be written in a microprocessor to produce a pulsed output for this quantity. Otherwise, VA calibration requires an accurate source. The ADE7763 provides a line cycle accumulation mode for calibration using an accurate source. In this method, the active energy accumulation rate is adjusted to produce a desired CF frequency. The benefit of using this mode is that the effect of the ripple noise on the active energy is eliminated. Up to 65,535 half line cycles can be accumulated, therefore providing a stable energy value to average. The accumulation time is calculated from the line cycle period, measured by the period register, and the number of half line cycles in the accumulation, fixed by the LINECYC register. Current and voltage rms offset calibration removes apparent energy offset. A gain calibration is also provided for apparent energy. Figure 70 shows an optimized calibration flow for active energy, rms, and apparent energy. Active and apparent energy gain calibrations can take place concurrently, with a read of the accumulated apparent energy register following that of the accumulated active energy register. Figure 69 shows the calibration flow for the active energy portion of the ADE7763. WATT GAIN CALIBRATION WATT OFFSET CALIBRATION PHASE CALIBRATION Figure 69. Active Energy Calibration WATT/VA GAIN CALIBRATION WATT OFFSET CALIBRATION RMS CALIBRATION PHASE CALIBRATION Figure 70. Apparent and Active Energy Calibration |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |