| 数据搜索系统,热门电子元器件搜索 |
|
ADP5065ACBZ-1-R7 数据表(PDF) 30 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP5065ACBZ-1-R7 数据表(HTML) 30 Page - Analog Devices |
|
30 / 40 page ![]() ADP5065 Data Sheet Rev. D | Page 30 of 40 Bit No. Mnemonic Access Default Description 2 EN_BAT_INT R/W 0 When high, the battery voltage thresholds interrupt is allowed. 1 EN_CHG_INT R/W 0 When high, the charger mode change interrupt is allowed. 0 EN_VIN_INT R/W 0 When high, the VINx pin voltage thresholds interrupt is allowed. Table 25. Interrupt Active, Register Address 0x0A Bit Descriptions Bit No. Mnemonic Access Default Description 7 IND_PEAK_INT R 0 When high, this bit indicates an interrupt caused by an inductor peak current limit. 6 THERM_LIM_INT R 0 When high, this bit indicates an interrupt caused by isothermal charging. 5 WD_INT R 0 When high, this bit indicates an interrupt caused by the watchdog alarm. The watchdog timer expires within 2 sec or 4 sec depending on the WDPERIOD setting of 32 sec or 64 sec, respectively. 4 TSD_INT R 0 When high, this bit indicates an interrupt caused by an overtemperature fault. 3 THR_INT R 0 When high, this bit indicates an interrupt caused by THR temperature thresholds. 2 BAT_INT R 0 When high, this bit indicates an interrupt caused by battery voltage thresholds. 1 CHG_INT R 0 When high, this bit indicates an interrupt caused by a charger mode change. 0 VIN_INT R 0 When high, this bit indicates an interrupt caused by VINx voltage thresholds. Table 26. Charger Status 1, Register Address 0x0B Bit Descriptions Bit No. Mnemonic Access Default Description 7 VIN_OV R Not applicable When high, this bit indicates that the voltage at the VINx pins exceeds VVIN_OV. 6 VIN_OK R Not applicable When high, this bit indicates that the voltage at the VINx pins exceeds VVIN_OK. 5 VIN_ILIM R Not applicable When high, this bit indicates that the current into a VINx pin is limited by the high voltage blocking FET and the charger is not running at the full programmed ICHG. 4 THERM_LIM R Not applicable When high, this bit indicates that the charger is not running at the full programmed ICHG but is limited by the die temperature. 3 CHDONE R Not applicable When high, this bit indicates the end of charge cycle has been reached. This bit latches on, in that it does not reset to low when the VRCH threshold is breached. [2:0] CHAGER_STATUS[2:0] R Not applicable Charger status bus. 000 = off. 001 = trickle charge. 010 = fast charge (CC mode). 011 = fast charge (CV mode). 100 = charge complete. 101 = suspend. 110 = trickle or fast charge timer expired. 111 = battery detection. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |