| 数据搜索系统,热门电子元器件搜索 |
|
ADP5065ACBZ-1-R7 数据表(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP5065ACBZ-1-R7 数据表(HTML) 17 Page - Analog Devices |
|
17 / 40 page ![]() Data Sheet ADP5065 Rev. D | Page 17 of 40 The ADP5065 also includes a number of significant features to optimize charging and functionality, including • Thermal regulation for maximum performance. • USB host current-limit accuracy: ±5 %. • Termination voltage accuracy: ±1 %. • Battery thermistor input with automatic charger shutdown in the event that the battery temperature exceeds limits. (Compliant with the JEITA Li-Ion battery charging temperature specification.) • Offloads processor to manage external pin (TRK_EXT) control to enable/disable trickle charging. • Direct external pin (IIN_EXT) control of 100 mA or 500 mA input current limit. • Optional external resistor programming input, V_WEAK_ SET, which is used for setting the VWEAK threshold. When the battery reaches the VWEAK threshold, the ADP5065 pulls down the SYS_EN_OK open-drain output flag. The flag can be used to hold off system turn on until the battery is at the minimum required level for a guaranteed system startup. CHARGER MODES Input Current Limit The VINx input current limit is controlled via an internal I2C ILIM register. The input current limit can also be controlled via the IIN_EXT pin as outlined in Table 7. Any change in the I2C default from 100 mA dominates over the pin setting. Table 7. IIN_EXT Operation IIN_EXT Function 0 100 mA input current limit or I2C programmed value 1 500 mA input current limit or I2C programmed value (or reprogrammed I2C value from 100 mA default) USB Compatibility The ADP5065 charger provides support for the following connections through the single connector VINx pin. The ADP5065 features a programmable input current limit to ensure compatibility with the requirements listed in Table 8. The current limit defaults to 100 mA to allow compatibility with a USB host or hub that is not configured. The I2C register default is 100 mA. An I2C write command to the ILIM register overrides the IIN_EXT pin and the I2C register default value can be reprogrammed for alternative requirements. When the input current limiting feature is used, the available input current may be too low for the charger to meet the pro- grammed charging current, ICHG, and the rate of charge is reduced. In this case, the VIN_ILIM flag is set. When connecting voltage to VINx without having the proper voltage level on the battery side, the HV blocking part is in a state wherein it draws only 1.3 mA (typical) of current until the VIN has reached the VIN_OK level. Table 8. Input Current Compatibility with Standard USB Limits Mode Standard USB Limit ADP5065 Function USB (China Only) 100 mA limit for stan- dard USB host or hub 100 mA input current limit or I2C programmed value 300 mA limit for Chinese USB specification 300 mA input current limit or I2C programmed value USB 2.0 100 mA limit for stan- dard USB host or hub 100 mA input current limit or I2C programmed value 500 mA limit for stan- dard USB host or hub 500 mA input current limit or I2C programmed value USB 3.0 150 mA limit for super speed USB 3.0 host or hub 150 mA input current limit or I2C programmed value 900 mA limit for super speed, high speed USB host or hub charger 900 mA input current limit or I2C programmed value Dedicated Charger 1500 mA limit for dedicated charger or low/full speed USB host or hub charger 1500 mA input current limit or I2C programmed value Trickle Charge Mode A deeply discharged Li-Ion cell may exhibit a very low cell voltage making it unsafe to charge the cell at high current rates. The ADP5065 charger uses a trickle charge mode to reset the battery pack protection circuit and lift the cell voltage to a safe level for fast charging. A cell with a voltage below VTRK_DEAD is charged with the trickle mode current, ITRK_DEAD. During trickle charging mode, the CHARGER_STATUS register is set. During trickle charging, the ISO_Sx node is regulated to VISO_STRK by the dc-to-dc converter and the battery isolation FET is off, which means the battery is isolated from the system power supply. Trickle charging can be controlled via the TRK_EXT external pin (see Table 9). Note that any change in the I2C EN_TRK bit dominates over the pin setting. Table 9. TRK_EXT Operation TRK_EXT Function 0 Trickle charge enabled 1 Trickle charge disabled Trickle Charge Mode Timer The duration of trickle charge mode is monitored to ensure the battery is revived from its deeply discharged state. If trickle charge mode runs for longer than 60 minutes without the cell voltage reaching VTRK_DEAD, a fault condition is assumed and charging stops. The fault condition is asserted on the CHARGER_STATUS register, allowing the user to initiate the fault recovery procedure specified in the Fault Recovery section. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |