| 数据搜索系统,热门电子元器件搜索 |
|
UCS2113 数据表(PDF) 19 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS2113 数据表(HTML) 19 Page - Microchip Technology |
|
19 / 62 page ![]() 2016-2021 Microchip Technology Inc. and its subsidiaries DS20005680B-page 19 UCS2113 FIGURE 5-2: Wake from Sleep using SMBus Read. 5.1.3 ACTIVE STATE OPERATION Every time the UCS2113 enters the Active state, the port power switches are closed. The UCS2113 cannot be in the Active state (and therefore, the port power switch cannot be turned on) if any of the following conditions exist: •VS <VS_UVLO • PWR_EN1 and PWR_EN2 are disabled. 5.1.4 ERROR STATE OPERATION The UCS2113 will enter the Error state from the Active state when any of the following events are detected: • The maximum allowable internal die temperature (TTSD_HIGH) has been exceeded. •The TTSD_LOW die temperature has been exceeded and any of the following conditions is met: - a power switch operates in constant current mode - PWR_EN1 and/or PWR_EN2 controls transition from inactive to active. - it is a power up situation and PWR_EN1 and/or PWR_EN2 pins are active. • An overcurrent condition has been detected. • An undervoltage condition on either VBUS pin has been detected (see Section 5.3.4 “Undervoltage Lockout on VS”). • A back-voltage condition has been detected (see Section 5.3.2 “Back-voltage Detection”). • A discharge error has been detected. • An overvoltage condition on the VS pin. When the UCS2113 enters the Error state, the port power switch will be disabled while the ALERT# pin is asserted. It will remain off while in this power state. The UCS2113 will leave this state as determined by the fault handling selection. With the Auto-recovery fault handler, after the tCYCLE time period, the UCS2113 will check that all of the error conditions have been removed. If all of the error conditions have been removed, the UCS2113 will return to the Active state. If both PWR_EN1 and PWR_EN2 controls transition from active to inactive while the UCS2113 is in the Error state, the device will not enter the Sleep state. After the fault has been removed, the UCS2113 will not automat- ically enter the Sleep state if the EN_VBUS_DISCHG bit from the General Configuration 2 Register is not set (default setting). To enter the Sleep state, the PWR_EN pins must be toggled or an SMBus read register com- mand must be sent. 5.2 Communication The UCS2113 can operate in SMBus mode (see Section 7.0 “System Management Bus Protocol”) or Stand-Alone mode. The resistor connected to the COMM_ILIM pin determines the operating mode and the hardware-set ILIM setting, as shown in Table 5-3. Unless connected to GND or VDD, the resistors in Table 5-3 are external pull-down resistors. The SMBus address is specified in Section 7.2 “SMBus Address and RD/WR Bit”. 0101_1110 A invalid dataN P SMBus Read A 0001_0000 0101_1110 A valid data N P 0001_0000 S S tIDLE_SLEEP Sleep Sleep Dummy read returns invalid data and places device in temporary Active state Read returns valid data 0101_1111 A S 0101_1111 A S A Power State temporary Active state (not all functionality available) tSMB_WAKE TABLE 5-3: COMMUNICATION DECODE COMM_ILIM Pull Down Resistor (±1%) PWR_EN1 and PWR_EN2 Polarity ILIM (A) Total ILIM (A) (Note 1) Communication Mode GND Active-High 0.53 0.53 + 0.53 SMBUS 10 k Active-High 0.96 0.96 + 0.96 SMBUS 12 k Active-High 1.07 1.07 + 1.07 SMBUS 15 k Active-High 1.28 1.28 + 1.28 SMBUS 18 k Active-High 1.6 1.6 + 1.6 SMBUS |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |