| 数据搜索系统,热门电子元器件搜索 |
|
UCS2113 数据表(PDF) 42 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS2113 数据表(HTML) 42 Page - Microchip Technology |
|
42 / 62 page ![]() UCS2113 DS20005680B-page 42 2016-2021 Microchip Technology Inc. and its subsidiaries REGISTER 8-8: GENERAL CONFIGURATION 2 REGISTER (ADDRESS 12H) R/W-0 U-0 R/W-0 R/W-0 U R/W-0 U-1 U-0 ALERT2_MASK — DSCHG2 PWR_EN2S — EN_VBUS_DISCHG — — bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit C = Clear on Read -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 7 ALERT2_MASK: Mask errors for all interrupts in Register 8-4 except OV_LIM2 and TSD. 1 = The ALERT#2 pin will only assert if a OV_LIM2 or TSD is detected 0 = The ALERT#2 pin will be asserted if an error condition or indicator event is detected bit 6 Unimplemented bit 5 DSCHG2: Forces the VBUS2 to be reset and discharged when the UCS2113 is in the Active state and the EN_VBUS_DISCHG bit is logic '1'. Writing this bit to a logic '1' will cause the port power switch to be opened and the discharge circuitry to activate to discharge VBUS. Actual discharge time is controlled by DISCHG_TIME<1:0>. This bit must be cleared by the SMBus host after the forced VBUS discharge. 1 =VBUS2 discharge initiated 0 = Port 2 not in discharge bit 4 PWR_EN2S: Power Enable Port 2 override - This bit is OR’ed with the PWR_EN2 pin. Thus, if the polarity is set to active-high, either the PWR_EN2 pin or this bit must be ‘1’ to enable the port power switch. bit 3 Unimplemented bit 2 EN_VBUS_DISCHG: Enables VBUS discharge circuitry. If it is '0', it completely disables all the automatic VBUS discharges from happening and allows only manual VBUS discharges (the SMBus host must set and clear DISCHG_LOAD1 and DISCHG_- LOAD2 bits from the Current Limit Behavior Registers 23h and 24h). Setting DSCHG1 and DSCHG2 bits from the General Configuration 1 and 2 registers 11h and 12h does not have any effect in this case (Note 1). If it is '1', the VBUS is discharged automatically as described in Section 6.4, VBUS Discharge. The VBUS can be discharged manually by the SMBus host only by setting DSCHG1 and DSCHG2 bits from the General Configuration 1 and 2 Registers 11h and 12h. Setting DISCHG_LOAD1 and DISCHG_LOAD2 bits from the Current Limit Behavior Registers 23h and 24h doesn't have any effect in this case. bit 1-0 Unimplemented Note 1: When the automatic VBUS discharges are disabled (EN_VBUS_DISCHG is '0'), the UCS2113 will not check that the VBUS voltage is below the VTEST level after the manual VBUS discharges. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |