| 数据搜索系统,热门电子元器件搜索 |
|
UCS2113 数据表(PDF) 27 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS2113 数据表(HTML) 27 Page - Microchip Technology |
|
27 / 62 page ![]() 2016-2021 Microchip Technology Inc. and its subsidiaries DS20005680B-page 27 UCS2113 If the RATION_EN control is set to ‘0’ prior to reaching the charge rationing threshold, rationing will be disabled and the Total Accumulated Charge registers will be cleared. If the RATION_EN control is set to ‘0’ after the charge rationing threshold has been reached, the following additional steps occur: 1. RATION status bit will be cleared. 2. The ALERT# pin will be released if asserted by the rationing circuitry and no other conditions are present. 3. The PWR_EN controls are checked to determine the power state. Setting the RATION_RST control to ‘1’ will automatically reset the Total Accumulated Charge registers to 00_00h. If this is done prior to reaching the charge rationing threshold, the data will continue to be accumulated restarting from 00_00h. If this is done after the charge rationing threshold is reached, the UCS2113 will take action as shown in Table 6-3. Report Ignore Release ALERT# pin. Report and Disconnect Open port power switch. See the Report and Disconnect (default) in Table 6-2. Disconnect and Go to Sleep 1. Release the ALERT# pin 2. Open the port power switch 3. Enter the Sleep state. See the Disconnect and Go to Sleep in Table 6-2. Report and Disconnect Ignore 1. Release the ALERT# pin 2. Check the PWR_EN controls and enter the indicated power state if the controls changed Report Check the PWR_EN controls and enter the indicated power state if the controls changed Disconnect and Go to Sleep 1. Release the ALERT# pin 2. Enter the Sleep state. See the Disconnect and Go to Sleep in Table 6-2. Disconnect and Go to Sleep Ignore Check the PWR_EN controls and enter the indicated power state if the controls changed Report 1. Assert the ALERT# pin 2. Check the PWR_EN controls and enter the indicated power state if the controls changed Report and Disconnect 1. Assert the ALERT# pin 2. Check the PWR_EN controls to determine the power state, then enter that state, except that the port power switch will not be closed TABLE 6-4: EFFECTS OF CHANGING RATIONING BEHAVIOR AFTER THRESHOLD REACHED Previous Behavior New Behavior Actions Taken |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |