10 / 42 page ![]() ADE1202 Data Sheet Rev. 0 | Page 10 of 42 ABSOLUTE MAXIMUM RATINGS TA = 25°C, unless otherwise noted. Table 10. Parameter Rating VDD to GND −0.3 V to +3.7 V IN1, IN2 to GNDF −0.2 V to +2 V LOAD1, LOAD2 to GNDF −0.3 V to +7.7 V GATE to GNDF −0.3 V to +7.7 V Digital Input Voltage to GND −0.3 V to VDD + 0.3 V Digital Output Voltage to GND −0.3 V to VDD + 0.3 V Operating Temperature Industrial Range −40°C to +125°C Storage Temperature Range −65°C to +150°C Lead Temperature (Soldering, 10 sec)1 300°C Electrostatic Discharge (ESD) Human Body Model2 ±5 kV Field Induced Charged Device Model (FICDM)3 ±1.5 kV 1Analog Devices, Inc., recommends that reflow profiles used in soldering RoHS compliant devices conform to J-STD-020D.1 from JEDEC. Refer to JEDEC for the latest revision of this standard. 2 Applicable standard: ANSI/ESDA/JEDEC JS-001-2014. 3 Applicable standard: JESD22-C101F (ESD FICDM standard of JEDEC). Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. THERMAL RESISTANCE Thermal performance is directly linked to PCB design and operating environment. Careful attention to PCB thermal design is required. θJA is the junction to ambient thermal resistance. θJC is the junction to case thermal resistance. ΨJT is the junction to top characterization parameter. Table 11. Thermal Resistance1 Package Type θJA θJC ΨJT Unit CC-20-5 168 76 12 °C/W 1 Based on simulated data using a JEDEC 2s2p thermal test board in a JEDEC natural convection environment. See JEDEC specification JESD-51 for details. ESD CAUTION Table 12. Maximum Continuous Working Voltage1 Parameter Max Unit Reference Standard2 AC Voltage Bipolar Waveform Basic Insulation 636 V peak Lifetime limited by insulation lifetime per VDE-0884-11 Reinforced Insulation 537 V peak Lifetime limited by package creepage per IEC 60664-1 Unipolar Waveform Basic Insulation 1242 V peak Lifetime limited by package creepage per IEC 60664-1 Reinforced Insulation 621 V peak Lifetime limited by package creepage per IEC 60664-1 DC Voltage Basic Insulation 760 V peak Lifetime limited by package creepage per IEC 60664-1 Reinforced Insulation 380 V peak Lifetime limited by package creepage per IEC 60664-1 1 The maximum continuous working voltage refers to the continuous voltage magnitude imposed across the isolation barrier. See the Insulation Wear Out section for more details. 2 Insulation lifetime for the specified test condition is greater than 50 years. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |