| 数据搜索系统,热门电子元器件搜索 |
|
33982 数据表(PDF) 28 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
33982 数据表(HTML) 28 Page - NXP Semiconductors |
|
28 / 47 page ![]() 28 NXP Semiconductors 33982 FUNCTIONAL DEVICE OPERATION Previous Address SOA[2:0]=001 The data in bits OD1 and OD0 contain CSNS EN and IN_SPI programmed bits, respectively. Previous Address SOA[2:0]=010 The data in bit OD3 contain the programmed overcurrent high detection level (refer to Table 12), and the data in bits OD2, OD1, and OD0 contain the programmed overcurrent low detection levels (refer to Table 11). Previous Address SOA[2:0]=011 The data returned in bits OD1 and OD0 are current values for the overcurrent fault blanking time, illustrated in Table 13. Bit OD2 reports when the overcurrent detection timeout feature is active. OD3 reports whether the open load circuitry is active. Previous Address SOA[2:0]=100 The returned data contain the programmed values in the DICR. Previous Address SOA[2:0]=101 • SOA3 = 0. The returned data contain the programmed values in the OSDR. Bit OD3 (FSM_HS) reflects the state of the output in the Fail-safe mode after a watchdog timeout occurs. • SOA3 = 1. The returned data contain the programmed values in the WDR. Bit OD2 (WDTO) reflects the status of the watchdog circuitry. If WDTO bit is logic [1], the watchdog has timed out and the device is in Fail-safe mode. If WDTO is logic [0], the device is in Normal mode (assuming device is powered and not in the Sleep mode), with the watchdog either enabled or disabled. Previous Address SOA[2:0]=110 • SOA3 = 0. OD2, OD1, and OD0 return the state of the IN, FSI, and WAKE pins, respectively (Table 18). • SOA3 = 1. The returned data contains the programmed values in the UOVR register. Bit OD1 reflects the state of the undervoltage protection, while bit OD0 reflects the state of the overvoltage protection (refer to Table 16). Previous Address SOA[2:0]=111 Null Data. No previous register Read Back command received, so bits OD2, OD1, and OD0 are null, or 000. Table 17. Fault register OD7 OD6 OD5 OD4 OD3 OD2 OD1 OD0 x OTF OCHF OCLF OLF UVF OVF FAULT OD7 (x) = Don’t care. OD6 (OTF) = Overtemperature Flag. OD5 (OCHF) = Overcurrent High Flag. (This fault is latched.) OD4 (OCLF) = Overcurrent Low Flag. (This fault is latched.) OD3 (OLF) = Open Load Flag. OD2 (UVF) = Undervoltage Flag. (This fault is latched or not latched.) OD1 (OVF) = Overvoltage Flag. OD0 (FAULT) = This flag reports a fault and is reset by a read operation. Note The FS pin reports a fault and is reset by a new Switch-ON command (via SPI or direct input IN). Table 18. Pin register OD2 OD1 OD0 IN Pin FSI Pin WAKE Pin |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |