| 数据搜索系统,热门电子元器件搜索 |
|
M24C64-R 数据表(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M24C64-R 数据表(HTML) 31 Page - STMicroelectronics |
|
31 / 54 page ![]() DS6638 Rev 36 31/54 M24C64-W M24C64-R M24C64-F M24C64-DF DC and AC parameters 53 Table 20. 1 MHz AC characteristics Symbol Alt. Parameter(1) 1. Only for devices identified by the process letter K or T (devices qualified at 1 MHz). Min. Max. Unit fC fSCL Clock frequency 0 1 MHz tCHCL tHIGH Clock pulse width high 260 - ns tCLCH tLOW Clock pulse width low 500 - ns tXH1XH2 tR Input signal rise time (2) 2. There is no min. or max. values for the input signal rise and fall times. It is however recommended by the I²C specification that the input signal rise and fall times be less than 120 ns when fC < 1 MHz. (2) ns tXL1XL2 tF Input signal fall time (2) (2) ns tQL1QL2(3) 3. Characterized only, not tested in production. tF SDA (out) fall time 20(4) 4. With CL = 10 pF. 120 ns tDXCH tSU:DAT Data in setup time 50 - ns tCLDX tHD:DAT Data in hold time 0 - ns tCLQX(5) 5. To avoid spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA. tDH Data out hold time 50(6) 6. The previous products were specified with tCLQX longer than 50 ns. it should be noted that any tCLQX value longer than 50ns offers a safe margin when compared to the I2C-bus specification recommendations. -ns tCLQV(7) 7. tCLQV is the time (from the falling edge of SCL) required by the SDA bus line to reach either 0.3 VCC or 0.7 VCC, assuming that the Rbus × Cbus time constant is within the values specified in Figure 16. tAA Clock low to next data valid (access time) - 450 ns tCHDL tSU:STA Start condition setup time 250 - ns tDLCL tHD:STA Start condition hold time 250 - ns tCHDH tSU:STO Stop condition setup time 250 - ns tDHDL tBUF Time between Stop condition and next Start condition 500 - ns tWLDL(8)(3) 8. WC=0 set up time condition to enable the execution of a WRITE command. tSU:WC WC set up time (before the Start condition) 0 - µs tDHWH(9)(3) 9. WC=0 hold time condition to enable the execution of a WRITE command. tHD:WC WC hold time (after the Stop condition) 1 - µs tW tWR Write time - 5 ms tNS(3) - Pulse width ignored (input filter on SCL and SDA) -50(10) 10. The previous products were specified with tNS longer than 50 ns. it should be noted that the I2C-bus specification recommends a tNS value longer than 50ns. ns |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |