| 数据搜索系统,热门电子元器件搜索 |
|
L5965 数据表(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L5965 数据表(HTML) 19 Page - STMicroelectronics |
|
19 / 73 page ![]() Figure 9. Pre regulator BUCK1 PGND1 GL1 Sensen/p COMP1 VREG VREG BST1 VBAT1 GH1 PH1 Rsense VBUCK1 GAPG2206151644PS In dropout operation the external high-side MOSFET is kept always on; every fourth clock cycle it has to be turned off for 180ns to recharge bootstrap capacitor. This allows a maximum duty cycle of 98%. BUCK1 controller provides the following diagnostic: • Monitor of the output voltage is monitored by an independent circuit for UV/OV detection: thresholds are set via SPI. • Monitor of the Power Good thresholds: are set via SPI (at 5/10% of VBUCK1) and the status is provided via SPI bit. • Over Current Protection via current sense amplifier. • Over Temperature detection by a local thermal sensor. • PGND1 loss detection. If BUCK1 is set as Main BUCK pre-regulator: • If a UV/OV fault occurs, then Fault pin is asserted and the corresponding fault bit is set inside the SPI register, where can be read and cleared. RESET_B is always asserted in case of UV. In case of OV, it is possible to enable or disable the reset for all regulators together by OTP. The reset moves the device to REC state. • If OT occurs, the power stage is switched OFF with a 16 µs filter time. The output decreases until UV is detected. The regulator goes in REC state and can restart only when OT flag is reset. The corresponding SPI bit is set and FAULT pin is asserted. • The over current limitation is a cycle by cycle protection: when the fault happens, the corresponding fault bit (Buck_OC_STAT) is set in the SPI register. This bit doesn't change the regulator behavior. If the fault happens for 7 consequent cycles, the FAULT pin is asserted (latched). • If PGND1 ground loss occurs, all regulators are turned OFF, FAULT and RESET_B pins are asserted and device goes back to REC state. Until the fault is present, any tentative of turning on the regulator is ignored. If BUCK1 is set as BUCK post-regulator we have the same behavior as above, except that: L5965 Voltage regulators and features description DS12567 - Rev 3 page 19/73 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |