| 数据搜索系统,热门电子元器件搜索 |
|
CS4294/CS4298 数据表(PDF) 46 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4294/CS4298 数据表(HTML) 46 Page - Cirrus Logic |
|
46 / 66 page ![]() CS4202 46 DS549PP2 8.2 Powerdown Controls The Powerdown Control/Status Register (Index 26h) controls the power management func- tions. The PR[6:0] bits in this register control the internal powerdown states of the CS4202. Power- down control is available for individual subsections of the CS4202 by asserting any PRx bit or any com- bination of PRx bits. All powerdown states except PR4 and PR5 can be resumed by clearing the cor- responding PRx bit. Table 15 shows the mapping of the power control bits to the functions they man- age. When PR0 is ‘set’, the L/R ADCs and the Input Mux are shut down and the ADC bit in the Power- down Control/Status Register (Index 26h) is ‘cleared’ indicating the ADCs are no longer in a ready state. The same is true for PR1 and the DACs, PR2 and the analog mixer, PR3 and the voltage reference (Vrefout), and PR6 and the head- phone amplifier. When one of these bits is ‘cleared’, the corresponding subsystem will begin a power-on process, and the associated status bit will be ‘set’ when the hardware is ready. In a primary codec the PR4 bit powers down the AC-link, but all other analog and digital sub- systems continue to function. The required resume sequence from a PR4 state is either a Warm Reset or a New Warm Reset, depending on whether a D3hot or D3cold state has been entered. The PR5 bit disables all internal clocks and powers down the DACs and the ADCs, but maintains oper- ation of the BIT_CLK and the analog mixer. A Cold Reset is the only way to restore operation to the CS4202 after asserting PR5. To achieve a com- plete digital powerdown, PR4 and PR5 must be as- serted within a single AC output frame. This will also drive BIT_CLK ‘low’. The CS4202 does not automatically mute any input or output when the powerdown bits are ‘set’. The software driver controlling the AC ’97 device must manage muting the input and output analog signals before putting the part into any power management state. The definition of each PRx bit may affect a single subsection or a combination of subsections within the CS4202. Table 16 contains the matrix of subsections affected by the respective PRx func- tion. Table 17 shows the different operating power consumptions levels for different powerdown func- tions. PR Bit Function PR0 L/R ADCs and Input Mux Powerdown PR1 Front DACs Powerdown PR2 Analog Mixer Powerdown (Vref on) PR3 Analog Mixer Powerdown (Vref off) PR4 AC-link Powerdown (BIT_CLK off)* PR5 Internal Clock Disable PR6 Headphone Out Powerdown * Applies only to primary codec Table 15. Powerdown PR Bit Functions |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |