| 数据搜索系统,热门电子元器件搜索 |
|
L6460 数据表(PDF) 41 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6460 数据表(HTML) 41 Page - STMicroelectronics |
|
41 / 139 page ![]() L6460 Start-up configurations Doc ID 17713 Rev 1 41/139 8.3 Slave device mode In slave device mode, L6460 consider the nAWAKE pin as an input enable. Since this is now a digital pin, the current pull up source inside the nAWAKE circuit is disabled. At the startup, if the nAWAKE pin is found to be low for a period higher than tAWAKEFILT, L6460 enters directly in the “Low Power mode”; when nAWAKE pin is pulled high for a period higher than tAWAKEFILT, L6460 begins its start up procedure. 8.4 Master device mode In master device mode, L6460 begins its start up procedure without waiting for any external enable signal and it uses GPIO[5] pin to drive the nAWAKE pin of Slave devices. During the whole start up time, it forces its GPIO[5] pin at logic level “0” in order to maintain all slave devices in “Low Power mode” as previously described. When start up operations are completed, L6460 forces the GPIO[5] output to logic level “1” to enable the slave devices and keeps GPIO[5] output at high level until it senses an under-voltage on any of its System regulators. If firmware writes in the PwrCtrl register to set Master L6460 in “Low Power mode” it immediately forces GPIO[5] output to logic level “0” to force the slave devices to enter in “Low Power mode”, then it waits for TMASTWAIT time and it starts its “Low Power mode” sequence. 8.5 Single device mode In single device mode, the device behaves similarly to master device mode but: 1. It doesn’t use the GPIO[5] pin to drive slave devices. 2. It doesn’t wait for TMASTWAIT before entering in “Low Power mode”. 8.6 Sub-configurations for slave, master or single device modes Each slave, master or single device modes can be divided in other minor modes depending on the start-up sequence needed for L6460 internal regulators. Unless otherwise specified, in all the following modes the regulators included in the start up sequence are considered system regulators and they start in the sequence indicated. 8.6.1 Bridge mode In this configuration bridges 3 and 4 are not used as regulators and therefore can be configured by the firmware in any of their possible bridge modes. When in this mode the power-up sequence is: 1. Main switching regulator (VSWmain). 2. Main linear regulator (VLINmain). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |