23 / 47 page ![]() www.ams.com/AS8510 Revision 3.5 22 - 46 AS8510 Datasheet - Detailed Descr i p ti on 7.8 4-Wire Serial Port Interface The SPI interface is used as interface between the AS8510 and an external micro-controller to configure the device and access the status information. The micro-controller begins communication with the SPI which is configured as a slave. The SPI protocol is simple and the length of each frame is an integer multiple of bytes except when a transmission is started. Each frame has 1 command bit, 7 address/configuration bits, and one or more data bytes. The edge of CS and the level of SCLK during the start of a SPI transaction, determine the edge on which the data is transferred from the SPI and the edge on which the data is sampled by the slave. Table 29 describes the setting of the transfer and sampling edges of SCLK. Figure 9 shows the falling edge and rising edge for data transfer and data sampling respectively, when SCLK is HIGH on the falling edge of CS. Figure 9. Protocol for Serial Data Write with Length = 1 7.8.1 SPI Frame A frame is formed by a first byte for command and address/configuration and a following bit stream that can be formed by an integer number of bytes. Command is coded on the 1 first bit, while address is given on LSB 7 bits (see Table 30). If the command is read or write, one or more bytes follow. When the micro-controller sends more bytes (keeping CS LOW and SCLK toggling), the SPI interface increments the address of the previous data byte and writes/reads data to/from consecutive addresses. Table 29. CS and SCLK CS SCLK Description FALL LOW Serial data transferred on rising edge of SPI clock. Sampled at falling edge of SPI clock. FALL HIGH Serial data transferred on falling edge of SPI clock. Sampled at rising edge of SPI clock. ANY ANY Serial data transfer edge is unchanged. Table 30. Command Bits Command Bits Register Address or Transmission Configuration C0 A6 A5 A4 A3 A2 A1 A0 Table 31. Command Bits C0 Command <A6:A0> Description 0 WRITE ADDRESS Writes data byte on the given starting address. 1 READ ADDRESS Read data byte from the given starting address. CS SCLK SDI SDO 0 A6 A5 A4 A0 A1 A2 A3 D0 D1 D2 D3 D4 D5 D7 D6 Transfer edge Sampling edge Data D7 – D0 is moved to Address A4..A0 here |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |