35 / 63 page ![]() SAP5S / SAP51 Universal Actuator-Sensor Interface IC Data Sheet July 17, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 35 of 62 The filter output of each data port is preset to “0” after reset or as long as the Data_Exchange_Disable flag is set, respectively. Input Signal Filter Output Sampling Point Figure 8: Principle of Delay Mode input filtering (exemplary for Slave with Address 1) > 256 µs (-6.25%) DEXCHG Addr 1 DEXCHG Addr1 DEXCHG Addr 1 Slave Slave Slave Activation of Delay Mode depends on the E²PROM flags Delay_Mode and P1_Delay_Activation and the value of the Parameter Port P1 Output Register as shown in Table 22. Delay Mode cannot be activated when Safety Mode is enabled. Note: The input signal at Parameter Port P1 does not influence activation of Input Delay Mode at all. Only the master can change the activation status by sending a corresponding Write_Parameter (WPAR) request. Table 22: Activation of Delay Mode Delay_Mode P1_Delay_Activation Parameter P1 Output Register Delay Mode 0 X X OFF 1 0 X ON 1 1 1 OFF 1 1 0 ON 4.8.3. Synchronous Data I/O Mode Since the slaves in an AS-i network are called successively by the master, the data input and output operations of different slaves are not synchronized normally. If there is, however, an application that requests accurate synchronized data I/O timing, the respective slaves may be operated in the Synchronous Mode. Concerning the communication with the master, slaves running in the Synchronous Mode behave like regular slaves. However, the input data sampling as well as the output data driving is determined by the polling cycle of the respective AS-i network as described below. Activation of the SAP5 Synchronous Mode is related to the E²PROM flags Synchronous_Data_IO and P2_Sync_Activation (refer to Table 9) and the value of the Parameter Port P2 Output Register as follows: NOTE: The input signal at Parameter Port P2 does not influence activation of Synchronous Data I/O Mode at all. Only the master can change the activation status by sending a corresponding Write_Parameter (WPAR) request. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |