| 数据搜索系统,热门电子元器件搜索 |
|
SAP5SD-B-G1-R 数据表(PDF) 45 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SAP5SD-B-G1-R 数据表(HTML) 45 Page - List of Unclassifed Manufacturers |
|
45 / 63 page ![]() SAP5S / SAP51 Universal Actuator-Sensor Interface IC Data Sheet July 17, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 45 of 62 4.14. UART The UART performs a syntactical and timing wise analysis of the received telegrams at the AS-i input channel. It converts the pulse coded AS-i input signal into a Manchester-II-coded bit stream and provides the receive register with decoded telegram bits. The UART also realizes the Manchester-II-coding of a slave answer. In Master/Repeater Mode the output signal of the Manchester coder (AS-i pulse to MAN signal conversion) is resynchronized and forwarded to pin LED1. Any pulse timing jitters of the received AS-i signal become removed, as long as they stay within the specified maximum limits. If the received AS-i telegram does not pass one of the different error checks (see detailed description below), the LED1 output the output becomes inactive for a certain time periode, see chapter 4.19.3. The comparator stages at the AS-i-line receiver generate two pulse-coded output signals (p_pulse, n_pulse) disjoining the positive and negative telegram pulses for further processing. To reduce UART sensitivity on erroneous spike pulses, pulse filters suppress any p_pulse, n_pulse activity of less than 750 ns width. After filtering, the p_pulse and n_pulse signals are checked in accordance with the AS-i Complete Specification for following telegram transmission errors: Start_bit_error The initial pulse following a pause must have negative polarity. Violation of this rule is detected as Start_bit_error. The first pulse is the reference for bit decoding. The first bit detected shall be of the value 0. Alternating_error Two consecutive pulses must have different polarity. Violation of this rule is detected as Alternating_error. Note: A negative pulse shall be followed by a positive pulse and vice versa. Timing_error Within any master request or slave response, the digital pulses that are generated by the receiver are checked to start in periods of after the start of the initial negative pulse, where n = 1 ... 26 for a master request and n = 1 ... 12 for a slave response. Violation of this rule is detected as Timing_error. s s s n 500 . 1 875 . 0 ) 3 * ( Note: There is a certain pulse timing jitter associated with the receiver output signals (compared to the analog signal waveform) due to sampling and offset effects at the comparator stages. In order to take the jitter effects into account, the timing tolerance specifications differ slightly from the definitions of the AS-i Complete Specification. No_information_error Derived from the Manchester-II-Coding rule, either a positive or negative pulse shall be detected in periods of after the start of the initial negative pulse, where n = 1 ... 13 for a master request and n = 1 ... 6 for a slave response. Violation of this rule is detected as No_information_error. s s s n 500 . 1 875 . 0 ) 6 * ( Note: The timing specification relates to the receiver comparator output signals. There is a certain pulse timing jitter in the digital output signals (compared to the analog signal waveform) due to sampling and offset effects at the comparator stages. In order to take the jitter effects into account, the timing tolerance specifications differ slightly from the definitions of the AS-i Complete Specification. Parity_error The sum of all information bits in master requests or slave responses (excluding start and end bits, including parity bit) must be even. Violation of this rule is detected as Parity_error. End_bit_error The pulse to be detected after the start pulse shall be of positive polarity, where n = 13 (78 s) for a master request and n = 6 (36 s) for a slave response. Violation of this rule shall be detected as an End_bit_error. s s s n 500 . 1 875 . 0 ) 6 * ( Note: This stop pulse shall finish a master request or slave response. Length_error Telegram length supervision is processed as follows. If during the first bit time after the end pulse of a master request (equivalent to the 15 th Bit time) for synchronized slaves (during the first three bit times for not synchronized slaves, equivalent to the Bit times 15 to 17) or during the first bit time after the end pulse of a slave response (equivalent to the 8 th Bit time) a signal different from a pause is detected, a Length_error is detected. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |