| 数据搜索系统,热门电子元器件搜索 |
|
SAP5SD-B-G1-R 数据表(PDF) 41 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SAP5SD-B-G1-R 数据表(HTML) 41 Page - List of Unclassifed Manufacturers |
|
41 / 63 page ![]() SAP5S / SAP51 Universal Actuator-Sensor Interface IC Data Sheet July 17, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 41 of 62 Table 27: LED status indication Priority / Status LED1 / LED 2 Note 1. Power Off No power supply available gree n red 2. External Reset DSTRBn driven LOW for more than 90ms. 3. Periphery Fault alternating Periphery Fault signal generated at PFAULT input. 4. No data exchange (Address = 0) Slave is waiting for address assignment. Data Port communication is not possible. 5. No data exchange The IC was reset by the Communication Watchdog or by RES or BR01 master calls, thus the Data_Exchange_Disable flag is still set, prohibiting Data Port communication. IC is waiting for a Write_Parameter request. 1 6. Normal operation Data communication is established red green red green red green red red red red red 1 This status is not signaled if the Communication Watchdog is not activated (refer to chapter 4.17 Communication Monitor/Watchdog). The flashing frequency of any flashing status indication is 2 … 3 Hz. In case of the simultaneous occurrence of several states the status with the highest priority is signaled. 4.11.2. Master/Repeater Mode In Master/Repeater Mode LED1 provides the Manchester-II-coded, re-synchronized equivalent of the telegram signal received at the AS-i input channel. Every received AS-i telegram is checked for consistency with the protocol specifications and timing jitters become removed as long as they stay within the specified limits. In case a telegram error is detected, the output becomes inactive for a certain time periode, see chapter 4.19.3. LED2 is always logic HIGH (high impedance) in Master/Repeater. In such applications, the green LED shall be connected to Pin UOUT or different supply levels. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |