29 / 102 page ![]() 80960HA/HD/HT Advance Information Datasheet 23 3.3 Package Thermal Specifications The 80960Hx is specified for operation when TC (case temperature) is within the range of 0°C–85°C. TC may be measured in any environment to determine whether the 80960Hx is within the specified operating range. Measure the case temperature at the center of the top surface, opposite the pins. Refer to Figure 5. TA (ambient temperature) is calculated from θCA (thermal resistance from case to ambient) using the equation: TA =TC –P*θCA Table 12 shows the maximum TA allowable (without exceeding TC) at various airflows and operating frequencies (fCLKIN). Note that TA is greatly improved by attaching fins or a heatsink to the package. P (maximum power consumption) is calculated by using the typical ICC as tabulated in Section 4.6, “DC Specifications” on page 32 and VCC of 3.3 V. Figure 5. Measuring 80960Hx PGA Case Temperature Measure PGA/PQ4 temperature at center of top surface |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|