TNETX3150GGP 数据表(PDF) 70 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETX3150GGP 数据表(HTML) 70 Page - Texas Instruments |
|
70 / 113 page ![]() TNETX3150/TNETX3150A ThunderSWITCH™ 15-PORT 10-/100-MBIT/S ETHERNET™ SWITCH SPWS027F – FEBRUARY 1997 – REVISED SEPTEMBER 1997 70 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 QMU – DRAM controller (continued) The address lines are arranged to permit a wide range of memory sizes to be connected to a maximum of 22 address lines. The address lines are organized as shown in Table 13. Table 13. Address-Line Organization TERMINAL NAME DX2 DX1 DX0 DA7 DA6 DA5 DA4 DA3 DA2 DA1 DA0 Address bit valid during DRAS 21 19 17 15 14 13 12 11 10 9 8 Address bit valid during DCAS 20 18 16 7 6 5 4 3 2 1 0 This prohibits the alignment of buffers to cross a page boundary, reducing buffer management complexity and maintaining a high bandwidth. address compare unit The address compare unit provides the switching information required to route the data packets. The source and destination Ethernet addresses are examined. Source addresses are used to determine the port’s address. Destination addresses are used to determine the packet destination. If a match is found, the appropriate destination channel address is generated and provided to the other internal components. Each channel (except the uplink port) has an address compare register (see Figure 29). Each register holds a 48-bit Ethernet address. The Ethernet source address is taken from a received frame and assigned to the channel on which it was received. This occurs for each frame received. The destination address is compared to the address registers. If matched, the channel address for the port is assigned. If no match is found for the destination address, the frame is handled according to the ADRDIS and BRUN option bits. If BRUN (broadcast to unassigned) is set, an unmatched frame is broadcast to all ports with unassigned addresses (requires IOBMOD bit to be set). If BRUN is reset, the frame is handled according to the ADRDIS bit for the uplink (port 00). If the ADRDIS bit for port 00 is set, the unmatched frame is discarded. If reset, the unmatched frame is transmitted from the uplink. The address compare registers learn their Ethernet address, used for comparison, from the source address of a received frame. The port address registers can be fully accessed via the DIO interface. This allows ports to be set up and secured under management control, or port address monitored. For further details, see the description of the TNETX3150/TNETX3150A registers. As the frame is loaded the source address is compared against the source address attributed to that port. If the address has changed and the port address acquired by the TNETX3150/TNETX3150A was secured, the port may be suspended or disabled and an error logged. During this comparison, it is possible to detect multiple entries of the same address in the compare unit. This also is an error, and it is meaningless to have the same address applied to multiple ports. If external address matching logic is not used, ports (1–14) must be confined to desktop (single address) and not multiple-address switching. The uplink (port 00) supports multiple-address switching. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |