| 数据搜索系统,热门电子元器件搜索 |
|
AD6676EBZ 数据表(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD6676EBZ 数据表(HTML) 22 Page - Analog Devices |
|
22 / 90 page ![]() AD6676 Data Sheet Rev. D | Page 22 of 90 TERMINOLOGY Noise Figure (NF) NF is the degradation in SNR performance (in dB) of an input signal having a noise density of −174 dBm/Hz after it passes through a component or system. Mathematically, NF = 10 × log(SNRIN/SNROUT) The noise figure of the AD6676 is determined by the equation NF = PIN − (10 × log(BW)) − (−174.0 dBm/Hz) − SNR where: PIN is the input power of an unmodulated carrier. BW is the noise measurement bandwidth. −174.0 dBm/Hz is the thermal noise floor at 290 K. SNR is the measured signal-to-noise ratio in dB of the AD6676. Note that PIN is set to a low level (that is, <−40 dBm) to minimize any degradation in measured SNR due to phase noise from either the input signal or Σ-Δ ADC clock source. Noise Spectral Density (NSD) NSD is the noise power normalized to 1 Hz bandwidth (at a particular frequency) relative to the full scale of the ADC (dBFS) and hence is given in units of dBFS/Hz. The AD6676, being a Σ-Δ ADC, displays a uneven NSD across its IF pass band. Both the worst-case NSD as well as NSD at the pass band center are reported. Note that NSD is calculated from the IBN measured over a 5 MHz bandwidth. In-Band Noise (IBN) IBN is the integrated noise power measured over a user defined bandwidth relative to the full scale of the ADC (dBFS). This bandwidth is typically equal to the IF pass band setting (BW) of the AD6676, unless otherwise noted. Input Second-Order Intercept (IIP2) IIP2 is a figure of merit used to quantify the second-order intermodulation distortion (IMD2) of a component or system. Two equal amplitude unmodulated carriers at specified frequencies (f1 and f2) injected into a nonlinear system exhibiting second-order nonlinearities produce IMD components at f1 − f2 and f1 + f2. For the AD6676, the two frequencies are situated at ½ the IF frequency (with a 2 MHz offset) at a power level corresponding to −6 dBFS at the IF center frequency with only the intermodulation term at f1 + f2 considered. IIP2 is the extrapolated tone power at which the intermodulation terms and the input tones have equal amplitude. IIP2 = PIN − IMD2 Input Third-Order Intercept (IIP3) IIP3 is a figure of merit used to quantify the third-order intermodulation distortion (IMD3) of a component or system. Two equal amplitude unmodulated carriers at specified frequencies (f1 and f2) injected into a nonlinear system exhibiting third-order nonlinearities produce IMD components at 2 f1 − f2 and 2 f2 − f1. IIP3 is the extrapolated tone power at which the intermodulation terms and the input tones have equal amplitude. IIP3 = PIN – IMD3/2 Note that the third-order IMD performance of an ADC does not necessarily follow the 3:1 rule that is typical of RF/IF linear devices. IMD performance is dependent on the dual tone frequencies, signal input levels, and ADC clock rate. Worst In-Band Spur (SFDR) Worst in-band spur is the worst spur falling in the IF pass band relative to the full scale of the ADC (dBFS) when a single tone with defined power level is stepped (typically 1 MHz increments) across a user defined frequency range. Note that this worst spur can often be an image (or clock) related spur depending on the IF, BW, and IQ output data rate setting of the AD6676 and on the sweep range. Signal Transfer Function (STF) STF is the frequency response of the output signal of the ADC relative to a swept single tone at its input. The STF presented for different AD6676 setup conditions in the Typical Performance Characteristics section shows the STF over the IF pass band after the digital filter to highlight pass band flatness. The wideband STF response is measured before the digital filter to highlight the pass band response of the AD6676 Σ-Δ ADC. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |