19 / 45 page ![]() Datasheet TEK.COM 20 Measurement Accuracy 4 Example of C/G Measurement Accuracy Frequency Measured Capacitance C Accuracy 1 G Accuracy 1, 2 10 MHz 3 1 pF ±0.92% ±590 nS 10 pF ±0.32% ±1.8 µS 100 pF ±0.29% ±17 µS 1 nF ±0.35% ±99 µS 1 MHz 1 pF ±1.17% ±64 nS 10 pF ±0.19% ±65 nS 100 pF ±0.10% ±610 nS 1 nF ±0.09% ±4 µS 100 kHz 10 pF ±0.31% ±28 nS 100 pF ±0.18% ±59 nS 1 nF ±0.10% ±450 nS 10 nF ±0.10% ±3 µS 10 kHz 100 pF ±0.31% ±15 nS 1 nF ±0.15% ±66 nS 10 nF ±0.08% ±450 nS 100 nF ±0.10% ±3 µS 1 kHz 1 nF ±0.82% ±40 nS 10 nF ±0.40% ±120 nS 100 nF ±0.10% ±500 nS 1 µF ±0.15% ±10 µS Notes 1. The capacitance and conductance measurement accuracy is specified under the following conditions: D X < 0.1. 2. Conductance accuracy is specified as the maximum conductance measured on the referenced capacitor. 3. These specs are typical, non-warranted, apply at 23°C, and are provided solely as useful information. 4. Integration time: 1 s or 10 s below 10 kHz. Test signal level: 30 mV rms. At the rear panel of the 4210-CVU. All specifications apply at 23°C ±5°C, within one year of calibration, RH between 5% and 60%, after 30 minutes of warmup. CVU Supplemental Cable Specification 3 These specifications are typical, non-warranted, apply at 23°C, and are provided solely as useful information. 4210-CVU Typical C Accuracy with 1.5m Cables (supplemental) Measured Capacitance 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 1 pF N/A ±8.38% ±1.95% ±0.43% N/A 10 pF N/A ±0.94% ±0.21% ±0.18% ±1% 100 pF N/A ±0.29% ±0.20% ±0.15% ±1% 1 nF ±0.72% ±0.17% ±0.12% ±0.16% ±2% 10 nF ±0.28% ±0.12% ±0.13% ±0.55% N/A 100 nF ±0.12% ±0.13% ±0.22% ±1.14% N/A 1 µF ±0.17% ±0.21% N/A N/A N/A 4210-CVU Typical C Accuracy with 3m Cables (supplemental) Measured Capacitance 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 1 pF N/A ±8.5 % ±2.05% ±0.57% N/A 10 pF N/A ±0.96% ±0.23% ±0.21% N/A 100 pF N/A ±0.29% ±0.20% ±0.17% N/A 1 nF ±0.72% ±0.17% ±0.12% ±0.18% N/A 10 nF ±0.28% ±0.12% ±0.13% ±0.65% N/A 100 nF ±0.12% ±0.13% ±0.22% ±1.16% N/A 1 µF ±0.17% ±0.21% N/A N/A N/A Notes 1. The capacitance and conductance measurement accuracy is specified under the following conditions: D X < 0.1. 2. Conductance accuracy is specified as the maximum conductance measured on the referenced capacitor. 3. These specs are typical, non-warranted, apply at 23°C, and are provided solely as useful information. 4. Integration time: 1 s or 10 s below 10 kHz. Test signal level: 30 mV rms. At the rear panel of the 4210-CVU. All specifications apply at 23°C ±5°C, within one year of calibration, RH between 5% and 60%, after 30 minutes of warmup. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |