29 / 45 page ![]() Datasheet TEK.COM 30 7. Remote Preamplifier/Switch Module The 4225-RPM enables automatic switching between I-V, C-V and Pulsed I-V measurements, allowing you to choose the appropriate measurement without recabling your test setup. Additionally, the RPM expands the range of the 4225-PMU Pulse Measure Module. 4225-RPM General Information Inputs Three inputs. SMU Force, SMU Sense, CVU Pot, CVU Cur, RPM Control Outputs One channel Input connector Triaxial (f), two SMA (f), two HDMI Output connector Triaxial (f), two Dimensions 1.34 in. wide × 4.9 in. deep × 3.0 in. tall (3.4 cm wide × 12.5 cm deep × 7.6 cm tall) Dimensions with base 1.34 in. wide × 4.9 in. deep × 3.8 in. tall (3.4 cm wide × 12.5 cm deep × 9.6 cm tall) Weight 8.6 oz. (245 g) (with base: 13.4 oz. (381 g)) Optional Accessories Magnetic base Vacuum base RPM Current Measurement Timing parameters, typical 1 with the 4225-PMU and 4225-RPM Remote Preamplifier/Switch Module 10V Range Current measure ranges 100 nA 1 µA 10 µA 100 µA 1 mA 10 mA Recommended minimum pulse width 2 134 µs 20.4 µs 8.36 µs 1.04 µs 370 ns 160 ns Recommended minimum measure window 2 10 µs 1.64 µs 1 µs 130 ns 40 ns 20 ns Recommended minimum transition time 3 1 µs 360 ns 360 ns 40 ns 30 ns 20 ns Noise 4 200 pA 2 nA 5 nA 50 nA 300 nA 1.5 µA Settling time 5 100 µs 15 µs 6 µs 750 ns 250 ns 100 ns Notes 1. All typical values measured with an open circuit. 2. Using default measure window of 75% to 90% of pulse top. Recommended minimum pulse width = (Settling Time) / 75%. 3. Recommended rise/fall time to minimize overshoot. 4. RMS noise measured over the Recommended Minimum Measure Window for the given voltage or current range, typical. 5. Time necessary for the signal to settle to the DC accuracy level. (Example: 10 mA settling time on the PMU 10 V range is defined when the signal is within 1.25% of the final value. This calculation: Accuracy = 0.25% + 100 µA = 0.25% + (100 µA/10 mA) = 0.25% + 1% = 1.25%). Current Measurement Accuracy 4225-PMU and RPM Combined 10 V Range Current measure ranges 100 nA 1 µA 10 µA 100 µA 1 mA 10 mA Accuracy (DC) ±(0.5% + 1 nA) ±(0.5% + 1 nA) ±(0.5% + 30 nA) ±(0.5% + 100 nA) ±(0.5% + 1 µA) ±(0.5% +10 µA) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |