| 数据搜索系统,热门电子元器件搜索 |
|
ADV7393 数据表(PDF) 55 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADV7393 数据表(HTML) 55 Page - Analog Devices |
|
55 / 96 page ![]() ADV7390/ADV7391/ADV7392/ADV7393 Rev. 0 | Page 55 of 96 ED/HD SHARPNESS FILTER AND ADAPTIVE FILTER CONTROLS Subaddress 0x40, Subaddress 0x58 to Subaddress 0x5D There are three filter modes available on the ADV739x: sharpness filter mode and two adaptive filter modes. ED/HD Sharpness Filter Mode To enhance or attenuate the Y signal in the frequency ranges shown in Figure 74, the ED/HD sharpness filter must be enabled (Subaddress 0x31, Bit 7 = 1) and the ED/HD adaptive filter must be disabled (Subaddress 0x35, Bit 7 = 0). To select one of the 256 individual responses, the corresponding gain values, ranging from −8 to +7 for each filter, must be programmed into the ED/HD sharpness filter gain register at Subaddress 0x40. ED/HD Adaptive Filter Mode In ED/HD adaptive filter mode, the following registers are used: • ED/HD Adaptive Filter Threshold A • ED/HD Adaptive Filter Threshold B • ED/HD Adaptive Filter Threshold C • ED/HD Adaptive Filter Gain 1 • ED/HD Adaptive Filter Gain 2 • ED/HD Adaptive Filter Gain 3 • ED/HD sharpness filter gain register To activate the adaptive filter control, the ED/HD sharpness filter and the ED/HD adaptive filter must be enabled (Subaddress 0x31, Bit 7 = 1, and Subaddress 0x35, Bit 7 = 1, respectively). The derivative of the incoming signal is compared to the three programmable threshold values: ED/HD Adaptive Filter Threshold A, Threshold B, and Threshold C (Subaddress 0x5B, Subaddress 0x5C, and Subaddress 0x5D). The recommended threshold range is 16 to 235, although any value in the range of 0 to 255 can be used. The edges can then be attenuated with the settings in the ED/HD Adaptive Filter Gain 1, Gain 2, and Gain 3 registers (Subaddress 0x58, Subaddress 0x59 and Subaddress 0x5A), and the ED/HD sharpness filter gain register (Subaddress 0x40). There are two adaptive filter modes available. The mode is selected using the ED/HD adaptive filter mode control (Subaddress 0x35, Bit 6): • Mode A is used when the ED/HD adaptive filter mode control is set to 0. In this case, Filter B (LPF) is used in the adaptive filter block. In addition, only the programmed values for Gain B in the ED/HD sharpness filter gain register and ED/HD Adaptive Filter Gain 1, Gain 2, and Gain 3 registers are applied when needed. The Gain A values are fixed and cannot be changed. • Mode B is used when ED/HD adaptive filter mode control is set to 1. In this mode, a cascade of Filter A and Filter B is used. Both settings for Gain A and Gain B in the ED/HD sharpness filter gain register and ED/HD Adaptive Filter Gain 1, Gain 2, and Gain 3 registers become active when needed. FREQUENCY (MHz) FILTER A RESPONSE (Gain Ka) 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 FREQUENCY (MHz) FILTER B RESPONSE (Gain Kb) 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 FREQUENCY (MHz) 1.0 1.1 1.2 1.3 1.4 1.5 1.6 10 12 INPUT SIGNAL: STEP FREQUENCY RESPONSE IN SHARPNESS FILTER MODE WITH Ka = 3 AND Kb = 7 SHARPNESS AND ADAPTIVE FILTER CONTROL BLOCK 02 4 6 8 Figure 74. ED/HD Sharpness and Adaptive Filter Control Block |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |