| 数据搜索系统,热门电子元器件搜索 |
|
STV-6410-R01 数据表(PDF) 83 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STV-6410-R01 数据表(HTML) 83 Page - STMicroelectronics |
|
83 / 105 page ![]() CMOS Sensor; Customer Datasheet, Rev 3.0, 28 September 2000 VV5410 & VV6410 Commercial in confidence 83/105 cd5410-6410f-3-0.fm 9.6.3 No data write followed by same location read. When a location is to be read, but the value of the stored index is not known, a write message with no data byte must be written first, specifying the index. The read message then completes the message sequence. To avoid relinquishing the serial to bus to another master a repeated start condition is asserted between the write and read messages, i.e. no stop condition is asserted. In this example, the gain value (index = 3610) is read as 1510: As mentioned in the previous example, the read message is terminated with a negative acknowledge (A) from the master. 9.6.4 Same location multiple data write. It may be desirable to write a succession of data to a common location. This is useful when the status of a bit (e.g. auto-load) must be toggled. The message sequence indexes sf_setup register 108. If bit 0 is toggled high, low this will initiate a fresh auto-load. This is achieved by writing two consecutive data bytes to the sensor. There is no requirement to re-send the register index before each data byte. 9.6.5 Same location multiple data read When an exposure related value ( fineH, fineL, coarseH, coarse L, gain or clk_div) is written, it takes effect on the output at the beginning of the next video frame, (remember that the application of the gain value is a frame later than the other exposure parameters). To signal the consumption of the written value, a flag is set when any of the exposure or gain registers are written and is reset at the start of the next frame. This flag appears in status0 register and may be monitored by the bus master. To speed up reading from this location, the sensor will repeatedly transmit the current value of the register, as long as the master acknowledges each byte read. In the below example, a fineH exposure value of 0 is written, the status register is addressed (no data byte) and then constantly read until the master terminates the read message. Figure 40 : No data write followed by same location read. S A Sr A A A P 3310 3610 3310 3610 1510 A 0 0 No data write Read index and data SA A A 3210 2110 410 010 A 0 Write to pin_mapping Figure 41 : Same location multiple data write. 410 P Toggle control bit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |