314 / 429 page ![]() 314/429 J1850 Byte Level Protocol Decoder (JBLPD) J1850 BYTE LEVEL PROTOCOL DECODER (Cont’d) JBLPD ERROR REGISTER (ERROR) R247- Read only Register Page: 23 Reset Value: 0000 0000 (00h) ERROR is an eight bit read only register indicating error conditions that may arise on the VPWO and VPWI pins. A read of the ERROR register clears all bits (except for TTO and possibly the RBRK bit) which were set at the time of the read. The register is cleared after the MCU reset, while the CON- TROL.JE bit is reset, or while the CONTROL.JDIS bit is set. All error conditions that can be read in the ERROR register need to have redundant ERROR indicator flags because: – With JE set, the TDUF, RDOF, TRA, CRCE, IFD, & IBD bits in the ERROR register can only be cleared by reading the register. – The TTO bit can only be cleared by clearing the JE bit. – The RBRK bit can only be cleared by reading the ERROR register after the break condition has disappeared. Error condition indicator flags associated with the error condition are cleared when the error condi- tion ends. Since error conditions may alter the ac- tions of the transmitter and receiver, the error con- dition indicators must remain set throughout the error condition. All error conditions, including the RBRK condition, are events that get set during a particular clock cycle of the prescaled clock of the peripheral. The IFD, IBD, RBRK, and CRCE error conditions are then cleared when a valid EOF symbol is detected from the VPWI pin. The TRA error condition is a singular event that sets the cor- responding ERROR register bit, but this error itself causes no other actions. Bit 7 = TTO Transmitter Timeout Flag The TTO bit is set when the VPWO pin has been in a logic one (or active) state for longer than 1 ms. This flag is the output of a diagnostic circuit based on the prescaled system clock input. If the 4X bit is not set, the TTO will trip if the VPWO is constantly active for 1000 prescaled clock cycles. If the 4X bit is set, then the TTO will timeout at 4000 prescaled clock cycles. When the TTO flag is set then the di- agnostic circuit will disable the VPWO signal, and disable the JBLPD peripheral. The user program must then clear the JE bit to remove the TTO error. It can then retry the block by setting the JE bit again. The TTO bit can be used to determine if the exter- nal J1850 bus is shorted low. Since the transmitter looks for proper edges returned at the VPWI pin for its timing, a lack of edges seen at VPWI when trying to transmit (assuming the RBRK does not get set) would indicate a constant low condition. The user program can take appropriate actions to test the J1850 bus circuit when a TTO occurs. Note that a transmit attempt must occur to detect a bus shorted low condition. The TTO bit is cleared while the CONTROL.JE bit is reset or while the CONTROL.JDIS bit is set. TTO is cleared on reset. 0: VPWO line at 1 for less than 1 ms 1: VPWO line at 1 for longer than 1 ms Bit 6 = TDUF Transmitter Data Underflow. The TDUF will be set to a logic one if the transmit- ter expects more information to be transmitted, but a TXOP write has not occurred in time (by the end of transmission of the last bit). The transmitter knows to expect more information from the user program when transmitting messag- es or type 3 IFRs only. If an opcode is written to TXOP that does not include appending a CRC byte, then the JBLPD peripheral assumes more data is to be written. When the JBLPD peripheral has shifted out the data byte it must have the next data byte in time to place it directly next to it. If the user program does not place new data in the TX- DATA register and write the TXOP register with a proper opcode, then the CRC byte which is being kept tabulated by the transmitter is logically invert- ed and transmitted out the VPWO pin. This will en- sure that listeners will detect this message as an error. In this case the TDUF bit is set to a logic one. TDUF is cleared by reading the ERROR register with TDUF set. TDUF is also cleared on reset, while the CONTROL.JE bit is reset or while the CONTROL.JDIS bit is set. 0: No transmitter data underflow condition oc- curred 1: Transmitter data underflow condition occurred 70 TTO TDUF RDOF TRA RBRK CRCE IFD IBD 9 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |