354 / 429 page ![]() 354/429 CONTROLLER AREA NETWORK (bxCAN) CONTROLLER AREA NETWORK (Cont’d) CAN FILTER CONFIGURATION REG.2 (CFCR2) All bits of this register are set and cleared by soft- ware. Read / Write Reset Value: 0000 0000 (00h) Note: To modify FFAx and FSCx bits bxCAN must be in INIT mode. Bit 7 = FFA5 Filter FIFO Assignment for Filter 5 The message passing through this filter will be stored in the specified FIFO. 0: Filter assigned to FIFO 0 1: Filter assigned to FIFO 1 Bit 6:5 = FSC5[1:0] Filter Scale Configuration These bits define the scale configuration of Filter 5. Bit 4 = FACT5 Filter Active The software sets this bit to activate Filter 5. To modify the filter 5 registers (CF5R[7:0]), the FACT5 bit must be cleared. 0: Filter 5 is not active 1: Filter 5 is active Bit 3 = FFA4 Filter FIFO Assignment for Filter 4 The message passing through this filter will be stored in the specified FIFO. 0: Filter assigned to FIFO 0 1: Filter assigned to FIFO 1 Bit 2:1 = FSC4[1:0] Filter Scale Configuration These bits define the scale configuration of Filter 4. Bit 0 = FACT4 Filter Active The software sets this bit to activate filter 4. To modify the Filter 4 registers (CF4R[7:0]), the FACT4 bit must be cleared). 0: Filter 4 is not active 1: Filter 4 is active CAN FILTER CONFIGURATION REG.3 (CFCR3) All bits of this register are set and cleared by soft- ware. Read / Write Reset Value: 0000 0000 (00h) Bit 7 = FFA7 Filter FIFO Assignment for Filter 7 The message passing through this filter will be stored in the specified FIFO. 0: Filter assigned to FIFO 0 1: Filter assigned to FIFO 1 Bit 6:5 = FSC7[1:0] Filter Scale Configuration These bits define the scale configuration of Filter 7. Bit 4 = FACT7 Filter Active The software sets this bit to activate Filter 7. To modify the Filter 7 registers (CF7R[7:0]), the FACT7 bit must be cleared. 0: Filter 7 is not active. 1: Filter 7 is active. Bit 3 = FFA6 Filter FIFO Assignment for Filter 6 This bit allows the software to define whether the message passing through this filter will be as- signed to the receive FIFO0 or FIFO1. 0: Filter assigned to FIFO 0 1: Filter assigned to FIFO 1 Bit 2:1 = FSC6[1:0] Filter Scale Configuration These bits define the scale configuration of Filter 6. Bit 0 = FACT6 Filter Active The software sets this bit to activate Filter 6. To modify the Filter 6 registers (CF6R[7:0]), the FACT6 bit must be cleared. 0: Filter 6 is not active 1: Filter 6 is active 70 FFA5 FSC51 FSC50 FACT5 FFA4 FSC41 FSC40 FACT4 70 FFA7 FSC71 FSC70 FACT7 FFA6 FSC61 FSC60 FACT6 9 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |